11
0697-001 TR3 - 10/19
en
3.2 Display
LCD display with
- Four-digit volume display with digits measuring 17 mm in height for current dispensation
- Seven-digit display with digits measuring 6 mm in height for totalizers
- Display in liter units (optional: GAL, PTS, QTS) and flow rate (l/min)
- Low battery alert on display.
Minimum digital step of the measured value is 0.01 litres, minimum digital step of non-resettable
totalizer is 1 litre.
3.3 Keypad
Front membrane with three keys: "Reset", "Mode" and "Light".
3.4 Battery
Two 1.5 V batteries (AAA) with a minimum service life of approx. 5 years for a flow quantity of 1,000,000
liters during this period without use of the illumination. If the illumination is used, the service life
decreases with frequency of use.
The battery can be replaced after opening the housing (
→
chapter 8.2). Volume and calibration values
are not affected by battery replacement.
4. Transport and storage
4.1 Transport
Unpacking and checking condition of delivery
►
Unpack the flow meter on receipt and check for transport damages.
►
Report transport damages to the manufacturer immediately.
►
Check that the consignment is complete as ordered.
4.2 Storage
NOTICE
Damage of property as a result of incorrect storage!
►
Complete emptying of flow meter.
►
Store flow meter protected against weather effects and UV-rays.