Technical data
Delivery capacity data
13
© Lutz-Jesco GmbH 2017
Subject to technical changes.
170502
BA-10010-02-V01
Solenoid-diaphragm dosing pump
MAGDOS LA / LD
Operating instructions
5 Technical data
5.1 Delivery capacity data
Please note that some of this data only represents guide values. The actual capacity of a dosing pump depends on various factors. For approximate
values of the delivery capacity at different pressures, refer to chapter 15 „Delivery characteristic curves“ on page 38.
Information
Value
MAGDOS LA / LD Size
05
1
2
4
6
10
15
Delivery capacity at max. backpressure
l/h
0.36
0.76
1.9
3.4
6.2
9.0
13
ml/stroke
0.05
0.05
0.2
0.32
0.57
0.83
0.87
Max. delivery pressure
bar
16
8
6
3
Delivery capacity at average backpressure
l/h
0.54
1.1
2.3
3.8
6.8
10
15
ml/stroke
0.08
0.08
0.24
0.35
0.63
0.92
1
Average delivery pressure
bar
8
4
3
1
Max. stroke frequency
rpm
120
250
160
180
250
Suction height for non-gassing media (with
a filled suction line)
mWS
5
3
2
Table 10: Output data
5.2 Operating conditions and limits
Information
Value
MAGDOS LA / LD Size
05 – 15
Approved ambient temperature
°C
5 – 45 (with PVC components 5 – 40)*
Relative humidity
%
max. 90
Max. sound pressure level (depressurised)
dB(A)
68 – 75
Max. sound pressure level (at test pressure)
dB(A)
65 – 70
Max. supply pressure
mbar
800
Viscosity limits
mPa∙s
300** / 1000***
Adjustable dosing range
%
0 – 100
Table 11: Operating conditions and limits
* Use of the dosing pump at ambient temperatures below 5 °C must be checked individually. In such cases, please contact the manufacturer.
** With a viscosity of ~300 mPa∙s and above, you must use spring-loaded valves.
*** If the viscosity is above 1000 mPa∙s, this must be checked individually and the stroke frequency must be between 50 and 100 strokes/min.
Summary of Contents for MAGDOS LA