3)There are two " Integration time " modes :
Mode 1 : Integration from the " Zero second "
Mode 2 : Integration from the " Existing time "
Mode 1 : Integration from the " Zero second "
a. Press the " TIME Button " ( 3-6, Fig. 1 ) once, the left
lower Display will show " 00.00 " ( zero minute and
zero second ).
b. Press the " ENTER Button " ( 3-8, Fig. 1 ) once, the
meter will start the " Solar power integration "
measurement. The up main Display will show the
" Solar power integration value ", the left lower
Display will show the integration time.
Mode 2 : Integration from the " Existing time "
Press the " ENTER Button " ( 3-8, Fig. 1 ) once, the
meter will start the " Solar power integration " procedures.
The up main Display will show the " Solar
power integration value ", the left lower Display will
show the real time information.
Note :
a. If press the " Clock Button " ( 3-6, Fig. 1 ) once
the left lower Display will change the time information
from " minute second " to " date hour "
b. During the measurement If press the " Exit
Button " 3-5, 3-7 , Fig. 1 " together > 1.5 seconds
will exit the " Solar power integration " function
and return to " Solar power " measurement screen.
c. During the Intergarion measuement, if press the the
" FUNCTION Button " ( 3-7, Fig. 1 ) > 1.5 SECONDS
( not release the button ), the Display will show the
" Integartion value " or the " Solar power value " in
sequence.
9