Lutron Electronics SPM-1116SD Operation Manual Download Page 1

SD card real time Data Recorder

SOLAR POWER METER

Model : SPM-1116SD

Your purchase of this
SOLAR POWER METER
with SD CARD DATA
RECORDER marks a
step forward for you
into the field of
precision measurement.
A l t h o u g h   t h i s
DATALOGGER is a
complex and delicate
instrument, its durable
structure will allow
many years of use if
p r o p e r   o p e r a t i n g
t e c h n i q u e s   a r e
developed. Please read
t h e   f o l l o w i n g
instructions carefully
and always keep this
manual within easy
reach.

       OPERATION MANUAL

Summary of Contents for SPM-1116SD

Page 1: ...you into the field of precision measurement A l t h o u g h t h i s DATALOGGER is a complex and delicate instrument its durable structure will allow many years of use if p r o p e r o p e r a t i n g...

Page 2: ...Unit selection 6 4 3 Function selection 6 4 4 Solar power measurement 7 4 5 Transmission measurement 8 4 6 Solar power integration measurement 8 4 7 Data Hold 10 4 8 Data Record Max Min reading 10 4...

Page 3: ...n Real time SD memory card Datalogger it Built in Clock and Calendar real time data recorder sampling time set from 1 second to 3600 seconds Manual datalogger is available set the sampling time to 0 d...

Page 4: ...er integration Spectral 400 to 1100 nm response Measuring Solar power Unit W m 2 Btu ft 2 x h Transmission Solar power integration Wh m 2 Btu ft 2 Solar power Range Range 2000 W m 2 634 Btu ft 2 x h S...

Page 5: ...mory Card SD memory card 1 G to 16 G Advanced Set clock time Year Month Date setting Hour Minute Second Set sampling time Auto power OFF management Set beep Sound ON OFF Decimal point of SD card setti...

Page 6: ...cklight is OFF Approx DC 30 mA A If LCD backlight on the power consumption will increase approx 16 mA Weight 346 g 0 76 LB Dimension Main instrument 182 x 73 x 47 5 mm 7 1 x 2 9 x 1 9 inch Sensor prob...

Page 7: ...3 7 FUNCTION Button Button Zero Exit 3 8 LOG Button ENTER Button 3 9 Probe input socket 3 10 SD card socket 3 11 RS 232 Output Terminal 3 12 Reset Button 3 13 DC 9V Power Adapter Input Socket 3 14 Bat...

Page 8: ...The meter can select 2 kind solar unit as W m 2 or Btu ft 2 h Pressing the UNIT Button 3 5 Fig 1 1 5 SECONDS not release the button the Display will show the above units in sequence 2 Until the Displa...

Page 9: ...the Probe Plug 3 18 Fig 1 into the Probe Input Socket 3 9 Fig 1 2 Power on the meter Function should select to Solar power integration P I refer to chapter 4 3 3 To hold the Solar sensor 3 20 3 19 Fig...

Page 10: ...Note a The transmission function can be executed only the Original solar value is 1 W m 2 b During the measurement If press the Exit Button 3 5 3 7 Fig 1 together 1 5 seconds will exit the Transmissi...

Page 11: ...ress the ENTER Button 3 8 Fig 1 once the meter will start the Solar power integration procedures The up main Display will show the Solar power integration value the left lower Display will show the re...

Page 12: ...g with the maximum value will appear on the display b Press the REC Button 3 4 Fig 1 again the REC MIN symbol along with the minimum value will appear on the display c Press the REC Button 3 4 Fig 1 a...

Page 13: ...the SD card Format at first please refer chapter 7 6 page 19 c Time setting If the meter is used at first time it should to adjust the clock time exactly please refer chapter 7 1 page 17 d Decimal fo...

Page 14: ...page 18 b Pause the datalogger During execute the Datalogger function if press the LOG Button 3 8 Fig 1 once will pause the Datalogger function stop to save the measuring data into the memory circuit...

Page 15: ...g 1 to set the measuring position 1 to 99 for example room 1 to room 99 to identify the measurement location the lower Display will show P x x 1 to 99 x 1 to 99 b Finish the Datalogger During execute...

Page 16: ...fter exist the Datalogger then execute again the data will save to the SPM01001 XLS until Data column reach to 30 000 columns then will generate a new file for example SPM01002 XLS 3 Under the folder...

Page 17: ...SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name SPM01001...

Page 18: ...r the Advanced Setting mode then press the SET Button 3 6 Fig 1 once a while in sequence to select the eight main function the lower display will show dAtE Set clock time Year Month Date Hour Minute S...

Page 19: ...m Year value After the desired value is set press the Enter Button 3 8 Fig 1 once will going to next value adjustment for example first setting value is Year then next to adjust Month Date Hour Minute...

Page 20: ...uto power OFF management When the lower display show PoFF 1 Use the Button 3 5 Fig 1 or Button 3 7 Fig 1 to select the upper value to yES or no yES Auto Power Off management will enable no Auto Power...

Page 21: ...used the as the decimal point for example 20 6 1000 53 Under such situation it should change the Decimal character at first When the lower display show dEC 1 Use the Button 3 5 Fig 1 or Button 3 7 Fig...

Page 22: ...Adapter into DC 9V Power Adapter Input Socket 3 13 Fig 1 The meter will permanent power ON when use the DC ADAPTER power supply The power Button function is disable 9 BATTERY REPLACEMENT 1 When the l...

Page 23: ...method During the power on use a pin to press the Reset Button 3 12 Fig 1 once a while will reset the circuit system 11 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5...

Page 24: ...tes the following status D0 End Word D1 D8 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D9 Decimal Point DP position from right to the left 0 No D...

Page 25: ...ta bits Stop bit 1 Stop bit 12 PATENT The meter SD card structure already get patent or patent pending in following countries Germany Nr 20 2008 016 337 4 JAPAN 3151214 TAIWAN M 358970 M 359043 CHINA...