background image

  TABLE OF CONTENTS

1. FEATURES..................................................................1
2. SPECIFICATIONS........................................................1

 

3. FRONT PANEL DESCRIPTION.......................................3

3-1 Hold button.......................................................... 3
3-2       button ( Power button )...................................3
3-3 REC button........................................................... 3
3-4 LCD display...........................................................3
3-5 Wristlet.................................................................3
3-6 Anemometer Vane.................................................3
3-7 Battery Compartment / Cover.................................3
3-8 Buttons operation label..........................................3

4. MEASURING PROCEDURES..........................................4

4-1 Power on/off.........................................................4
4-2 LCD backlight on/off..............................................4
4-3 Function selection................................................. 4
4-4 Unit selection........................................................5
4-5 Air flow measurement............................................5
4-6 Hold Function...................................................... 6
4-7 REC ( Record ) function ....................................... 6
4-8 Auto power off disable........................................ 7

5. BATTERY REPLACEMENT.............................................7

Summary of Contents for SP-82AM

Page 1: ...r you into the field of precision measurement Although this METER is a complex and delicate instrument its durable structure will allow many years of use if p r o p e r o p e r a t i n g t e c h n i q...

Page 2: ...splay 3 3 5 Wristlet 3 3 6 Anemometer Vane 3 3 7 Battery Compartment Cover 3 3 8 Buttons operation label 3 4 MEASURING PROCEDURES 4 4 1 Power on off 4 4 2 LCD backlight on off 4 4 3 Function selection...

Page 3: ...uracy at high and low air velocity Built in microprocessor circuit assures excellent performance and accuracy Concise and compact buttons arrangement easy operation Memorize the maximum and minimum va...

Page 4: ...ft min 1 ft min m s 0 4 to 20 0 m s 0 1 m s 20 m s 3 F S km h 1 4 to 72 0 km h 0 1 km h 20 m s 4 F S MPH 0 9 to 44 7 mile h 0 1 MPH knots 0 8 to 38 8 knots 0 1 knots Remark ft min feet per minute MPH...

Page 5: ...3 FRONT PANEL DESCRIPTION Fig 1 3 1 Hold button 3 2 Button Power button 3 3 REC nutton 3 4 LCD display 3 5 Wristlet 3 6 Anemometer Vane 3 7 Battery Compartment Cover 3 8 Buttons operation label 3...

Page 6: ...be on 5 seconds then off automatically 4 3 Function selection The meter can select 2 kind function as a Anemometer b Air flow CMM CFM During power on press the Hold button continuously not release th...

Page 7: ...ection unit for all function are Measurement Unit Air velocity M S Km h mph knot FPM Air flow CMM CFM side it is normal 4 5 Air flow measurement 1 Power on select the function to Air flow measurement...

Page 8: ...cord and display the maximum and minimum reading values Start the Record function by pressing the REC Button once There will be a REC symbol on the display 2 With the REC symbol on the display a Press...

Page 9: ...unction just execute the REC function above chapter 4 7 then the Auto power off function will be canceled 5 BATTERY REPLACEMENT 1 When the LCD display shows symbol it is necessary to replace the batte...

Reviews: