3. FRONT PANEL DESCRIPTION

Fig. 1

3-1   Display

3-7   P1 input socket

3-2   Power Off/On Button

3-8   P2 input socket

3-3   Hold Button

3-9   RS-232 Output 

3-4   Zero Button

Terminal

3-5   " MAX./MIN. " Button

3-10  Battery Compartment

3-6   Unit Button

 /Cover

3-11  Plug/ quick coupler

4

Summary of Contents for PM-9102

Page 1: ...u into the field of precision measurement Although this MANOMETER is a complex and delicate instrument its durable structure will allow many years of use if proper operating techniques are developed P...

Page 2: ...splay 4 3 2 Power Off On Button 4 3 3 Hold Button 4 3 4 Zero Button 4 3 5 MAX MIN Button 4 3 6 Unit Button 4 3 7 P1 input socket 4 3 8 P2 input socket 4 3 9 RS 232 Output Terminal 4 3 10 Battery Compa...

Page 3: ...nel easy to offset the zero value Microprocessor circuit assures maximum possible accuracy provides special functions and features Super large LCD display with contrast adjustment for best viewing ang...

Page 4: ...s Data output RS 232 PC serial interface Sampling time Approx 0 8 second Power off Auto shut off saves battery life or manual off by push button Operating 0 to 50 32 to 122 temperature Operating Less...

Page 5: ...2 inch 0 05 inch Atmosphere 0 197 Atmosphere 0 001 Atmosphere Unit Max range Accuracy mbar 200 mbar 2 F S psi 2 9 psi 0 204 Note mm Hg 150 mm Hg 23 5 inch Hg 5 905 inch Hg F S full scale meter 2 040...

Page 6: ...1 3 1 Display 3 7 P1 input socket 3 2 Power Off On Button 3 8 P2 input socket 3 3 Hold Button 3 9 RS 232 Output 3 4 Zero Button Terminal 3 5 MAX MIN Button 3 10 Battery Compartment 3 6 Unit Button Co...

Page 7: ...et P1 input socket P2 input socket for accepting the differential pressure input Connecting the pipe along the Plug 3 11 Fig 1 to a P1 input socket 3 7 Fig 1 only b P2 input socket 3 8 Fig 1 only c Bo...

Page 8: ...ar on the display b Press the MAX MIN Button again the Min symbol along with the minimum value will appear on the display c To exit the memory record function press the MAX MIN Button continuously for...

Page 9: ...on during measurement by pressing the MAX MIN Button 3 5 Fig 1 6 RS232 PC SERIAL INTERFACE The instrument features an RS232 output via 3 5 mm Terminal 3 9 Fig 1 The connector output is a 16 digit data...