660A Clamp Meters
w/TightSight™ Display

Instruction Manual

COM

MIN

MAX

V/

Ω

CAT.III 1000V

MAX

750V

1000V

CAT.IV 600V

HOLD

OFF

V

V

Ω

Hz

66

INRUSH

CAT.III 1000V

CAT.IV 600V

660A

True RMS

A

660

61-766

Read First:  Safety Information

Understand and follow operating instructions carefully.  Use the meter only as specified in
this manual; otherwise, the protection provided by the meter may be impaired.

WARNING

To avoid possible electric shock, personal injury or death, follow these guidelines:

• Do not use if meter appears damaged.  Visually inspect the meter to ensure case is not

cracked and back case is securely in place.

• Inspect and replace leads if insulation is damaged, metal is exposed, or probes are

cracked.  Pay particular attention to the insulation surrounding the connectors.

• Do not use meter if it operates abnormally as protection maybe impaired.  
• Do not use during electrical storms or in wet weather.
• Do not use around explosive gas, dust, or vapor.
• Do not apply more than the rated voltage to the meter. 
• Do not use without the battery and the back case properly installed.
• Replace battery as soon as battery indicator         appears to avoid false readings.
• Remove the test leads from the circuit prior to removing battery cover.
• Do not attempt to repair this unit as it has no user-serviceable parts.

CAUTION

To protect yourself, think "Safety First":
• Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution.
• Use appropriate personal protective equipment such as safety glasses, face shields,

insulating gloves, insulating boots, and/or insulating mats.

• Before each use:

-

Perform a continuity test by touching the test leads together to verify the 
functionality of the battery and test leads.

-

Use the 3 Point Safety Method.  (1) Verify meter operation by measuring a known 
voltage.  (2) Apply meter to circuit under test.  (3) Return to the known live voltage 
again to ensure proper operation.

• Use the proper terminals, functions and range for your measurements.
• Never ground yourself when taking electrical measurements.
• Connect the black common lead to ground or neutral before applying the red test lead to

potential voltage.  Disconnect the red test lead from the voltage first.

• Always work with a partner.
• When using the probes, keep fingers as far behind the probe tips as possible.

600

V

V

X

000V

750V

DCAC AMPS

TightSight™ Display

ND 4960-5 61-764-766-768 Ins  3/17/08  6:46 AM  Page 1

Summary of Contents for 61-764

Page 1: ...Replace battery as soon as battery indicator appears to avoid false readings Remove the test leads from the circuit prior to removing battery cover Do not attempt to repair this unit as it has no use...

Page 2: ...ges Bright bold backlight Cat IV 600V Cat III 1000V Model Specific Features 61 764 model is averaging sensing rms calibrated 61 766 model is true rms sensing measures capacitance frequency and lower c...

Page 3: ...record max min values over a time period 30 min the Auto Power Off APO feature must be defeated Data Hold Feature Press the Hold button on the side of the meter to toggle in and out of the data hold...

Page 4: ...ense the level of resistance and beep if the resistance is less than 40 to confirm that continuity is present Measuring Capacitance 61 766 66 660 INRUSH 66 660 INRUSH AC Voltage DC Voltage 66 660 INRU...

Page 5: ...764 61 766 150 hours continuous with Alkaline 61 768 Low Battery Indication The is displayed when battery voltage drops below operating level Power Supply 1 9V battery NEDA 1604 JIS 006P IEC 6F22 Inc...

Page 6: ...ject to verification of the defect or malfunction This warranty does not apply to defects resulting from abuse neglect accident unauthorized repair alteration or unreasonable use of the instrument Any...

Page 7: ...e los cables de prueba del circuito antes de quitar la tapa de la bater a No intente reparar esta unidad ya que no tiene piezas reparables por el usuario PRECAUCI N Para protegerse piense en la Seguri...

Page 8: ...com n COM 7 Pantalla inferior TightSight 8 Funda protectora de goma 9 Funciones de medida 10 Advertencia de alto voltaje Hi V 11 Retenci n de datos 12 M ximo M nimo 13 Inrush Corriente de irrupci n 14...

Page 9: ...s o m nimos medidos en un per odo de tiempo mayor que 30 minutos debe anularse la caracter stica de apagado autom tico Auto Power Off APO ZERO Funci n Modelo 61 768 nicamente Este modo se utiliza para...

Page 10: ...l de resistencia y emitir un pitido si la resistencia es menor que 40 para confirmar que existe continuidad CORRECTO Uso con divisor de l nea INCORRECTO Las corrientes se anulan CORRECTO S lo un con d...

Page 11: ...humedecido y detergente suave No use abrasivos ni disolventes Piezas de servicio y de repuesto Esta unidad no contiene piezas reparables por el usuario Si necesita piezas de repuesto o consultar sobre...

Page 12: ...or a IV de aislamiento categor a IV de sobrevoltaje Grado 2 de contaminaci n de acuerdo con IEC 644 Uso en interiores Gamas y precisiones Convertidor de CA El modelo 61 764 detecta valores promedio y...

Page 13: ...stras tiendas o los lugares de venta de bater as y acumuladores De esta forma cumple con sus obligaciones legales y contribuye a la protecci n ambiental Garant a Se garantiza este instrumento al compr...

Page 14: ...rri re du bo tier n est pas bien mont Remplacez la pile d s que le t moin de pile est affich afin d viter les fausses lectures Retirez les fils d essai du circuit avant de retirer le capuchon de pile...

Page 15: ...inal d entr e commun COM 7 Affichage inf rieur TightSight 8 Gaine caoutchout e de protection 9 Fonctions de mesure 10 Avertissement de haute tension Hi V 11 R tention de donn es 12 Maxi mini 13 Inrush...

Page 16: ...ne p riode de temps On quitte ce mode en appuyant sur le bouton max min pendant plus de 2 s Remarque Pour enregistrer les valeurs max min sur une p riode de plus de 30 mn il faut invalider la fonction...

Page 17: ...nce Ohms V rifiez que le circuit est d sexcit pour obtenir des mesures pr cises V rification de la continuit V rifiez que le circuit est d sexcit Le multim tre d tectera le niveau de r sistance et met...

Page 18: ...un chiffon humide et un d tergent doux N utilisez ni abrasifs ni solvants Entretien d pannage et pi ces de rechange Cet appareil ne comporte pas de pi ces r parables par l utilisateur En ce qui concer...

Page 19: ...Pour une utilisation l int rieur C US N12966 Page 26 Plages et pr cisions Convertisseur c a Le mod le 61 764 assure une d tection par calcul de moyenne il est talonn avec des valeurs efficaces r elle...

Page 20: ...t contribuez la protection de l environnement IDEAL INDUSTRIES INC Sycamore IL 60178 Etats Unis Service d assistance technique 877 201 9005 www testersandmeters com ND 4960 5 Fabriqu Taiwan Garantie C...

Reviews: