Pre-Installation

1.

Determine the number of dimmers to be ganged in the

same wallbox. If installing a single dimmer in a switchbox,
continue to the "Single Unit Installation" section on page 3.

2.

If more than one dimmer is being ganged in the same

wallbox, side sections can be removed to fit in existing
switchboxes. When controlling magnetic ballasts, breaking
side sections off the dimmer will reduce the maximum
number of lamps per dimmer. Use the following charts to
determine the maximum number of lamps per dimmer.

These products are covered under one or more of the following U.S. patents:
4,663,570; 4,894,587; 5,001,386; 5,041,763; 5,055,742; 5,173,643; 5,224,029 and
corresponding foreign patents. U.S. and foreign patents pending. Lutron, Hi-lume,
and Nova are registered trademarks and Eco-10 is a trademark of Lutron Electronics
Co., Inc.

1997  Lutron Electronics Co., Inc.

Installation Instructions
Please Leave for Occupant

Fluorescent Dimmers
NF-10, NF-20, NF-30

120VAC, 60Hz

NF-10-277, NF-20-277

277VAC, 60Hz

Package Contents and Part Identification

Control

Mounting

Screws

Slider

Faceplate

5 Wire

Connectors

Control
Shaft

Screwdriver

Important Notes
Please Read Before Installation

Switchbox and Location:  A single-gang switchbox (3"
high x 2" wide x 2

1

/

2

" deep) will service all individual Nova

dimmers. These dimmers are designed to operate in
ambient temperatures from 0

o

C (32

o

F) to 40

o

C (104

o

F).

Allow a minimum space of 4

1

/

2

" above and below the

dimmer for proper heat dissipation.

Short Circuit Check:  Check new installation for short
circuits prior to installing dimmer. With POWER OFF,
connect incoming neutral to the white wire, and the hot
wire to both ballast input wires (black wire with brown wire
or yellow/blue wire or orange wire, depending on ballast
used). Turn power ON. If lights do not work, or breaker
trips, a short is present. Correct the wiring and check
circuit again. Install dimmer only when short is no longer
present. This check should be done by a qualified
electrician.

Sockets:  Use only with rapid start lamp sockets. Lamp
disconnect sockets may be required for use with certain
manufacturer's ballasts. This is in order to meet U.L. and
NEC regulations and maintains personal safety standards.
Lutron does not require lamp disconnect sockets with their
ballasts. Refer to the manufacturer's ballast label for this
information.

Lamps:  Use only rapid start fluorescent lamps. Energy
Saver Lamps may NOT be used with this dimmer. 

With

magnetic ballasts only, do not mix different wattage
lamps in the same circuit. NOTE:  For proper dimming
performance lamps must be operated at full intensity for
100 hours prior to dimming.

Ballasts:  Use ONLY dimming ballasts listed on chart in
step 2 of Pre-Installation. 

With magnetic ballasts only, do

not mix 1 and 2 lamp ballasts in any one dimmer circuit. Do
not mix ballasts manufactured by more than one company.
Using single lamp ballasts will produce the most consistent
low end dimming level.

Multi-phased Applications (120/208-3 Phase):  In multi-
phased applications use a separate neutral for each phase
containing a dimmer. Contact the 

Lutron Technical

Assistance Hotline toll-free for Application Note #17,
"Common Neutral Interaction".

** Only NF-10 may be used with Lutron Ballasts. Total Amps are determined by
adding all ballast line currents as indicated on ballast label.

Lutron
Hi-lume

16 Amps

Eco-10

Electronic
Ballasts

NF-10**

Number of Side Sections Removed

None

One

Two

NF-10 NF-20 NF-30 NF-10 NF-20 NF-30 NF-10 NF-20

NF-30

Universal
550LTCP

12

24

36

9

22

34

6

19

31

502ATCP

*

12

24

36

9

20

32

4

18

28

Advance
DIM 140H

10

20

30

7

18

27

4

15

25

DIM 240H*

10

20

30

6

18

26

4

14

24

Valmont
8G5001W

12

24

36

9

22

34

6

19

31

8G5007W*

12

24

36

9

20

32

4

18

28

 can be used with 30W lamps

* 2 lamp ballast

NF-10 controls when used with

Lutron electronic dimming

ballasts do not require derating

when side sections are removed.

Figure A:  Derating Ballast Chart

120V Applications

277V Applications

Lutron
Hi-lume

8 Amps

Eco-10

** Only NF-10-277 may be used with Lutron Ballasts. Total Amps are determined by
adding all ballast line currents as indicated on ballast label.

Magnetic
Ballasts

Number of Side Sections Removed

None

One

Two

NF-10-277 NF-20-277 NF-10-277 NF-20-277 NF-10-277 NF-20-277

Magnetek
Universal
679LTCP

12

24

11

21

10

20

678LTCP

12

24

10

20

10

20

Controls

Ballasts

Controls
Ballasts

NF-10-277 controls when used

with Lutron electronic dimming

ballasts do not require derating

when side sections are removed.

Magnetic
Ballasts

Electronic
Ballasts

NF-10-277**

Units listed are maximum number of 

LAMPS per control

Units listed are maximum number of 

LAMPS per control

Reviews: