background image

4

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299 U.S.A.

Made and printed in U.S.A. 8/97  P/N 031-176 Rev. A

Warranty

Lutron will, at its option, repair or replace any unit that is defective in materials or
manufacture within one year after purchase. For warranty service, return unit to place
of purchase or mail to LUTRON at 7200 Suter Road, Coopersburg, PA 18036-1299,
postage prepaid.
This warranty is in lieu of all other warranties, express or implied, and the implied
warranty of merchantability is limited to one year from purchase. This warranty
does not cover the cost of installation, removal, or reinstallation, or damage
resulting from misuse, abuse, or damage resulting from improper wiring or
installation.
This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state. Some states do not allow the exclusion or limitation of
incidental or consequential damages or limitations on how long an implied warranty
may last, so the above limitations may not apply to you.

With one lamp ballast

NF-10, NF-20, NF-30, NF-10-277, NF-20-277
with Magnetic Ballast

NF-10/NF-10-277 with Lutron Ballast

Red

Dimmer

Hot

Neutral

Ground

Green or
Bare

White

Yellow

Black

Lamp

Ballast

*

* Lamp
  Disconnect
  Socket

White

Black

Red

Red

Y

e

llo

w/Blue or Bro

w

n

Blue

120VAC 60Hz

or

277VAC 60Hz

Red

Dimmer

Hot

Neutral

Ground

Green or
Bare

White

Yellow

Black

Lamp

*

* Lamp
  Disconnect
  Socket

Blue/White

White

Black

Red

Red

Y

ello

w/Blue or Bro

wn

Lamp

*

Yellow
Yellow

Blue

120VAC 60Hz

or

277VAC 60Hz

Ballast

With two lamp ballast

Black

Red

Hot

Neutral

120VAC 60Hz

or

277VAC 60Hz

White

Yellow

To Additional Ballasts

Orange

Black

White

Orange

Black

White

Lutron Dimming Ballast

Lutron Dimming Ballast

Dimmer

8.

For Lutron electronic ballasts ONLY:

This unit is factory-calibrated and does not require low-end
light adjustment when used with Lutron FDB or ECO-10
electronic ballasts. If lamps flicker or drop out at minimum
dimming level, there may be an installation error.
Continued use of the system in this mode will cause
premature lamp failure. If this condition exists, call the
Lutron Technical Assistance Hotline at: 1-800-523-
9466.

For magnetic ballasts ONLY:

a) Run lamps at full intensity (slider at top position) for 15

minutes to warm lamps. Note:  For proper dimming
performance lamps must be operated at full intensity for
100 hours prior to dimming.

b) After 15 minutes push slider to low intensity position (as

far down as possible without clicking off).

c) Locate trimpot adjustment shaft shown in Figure K.
d) Minimum light intensity is initially set at the factory. Use

the screwdriver provided to turn the trimpot screw
(inside trimpot shaft) clockwise to increase light level
and counterclockwise to lower light level.

9.

Replace slider and snap faceplate on dimmer by

pressing firmly at the top, center, and bottom tabs.

Worldwide Technical and Sales
Assistance

If you have questions concerning the installation or
operation or this product, call the 

Lutron Technical

Assistance Hotline:
(800) 523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call (610) 282-3800
Fax (610) 282-3090

Reviews: