  Expertise in LED control and dimming: 

•  Through the LED Center of Excellence, Lutron

R

 tests new LED fixtures and bulbs on an ongoing basis and has 

the widest compatibility list in the industry

• Lutron

R

 Phase adaptive dimmers can accommodate different types of loads on the same unit (different 

channel).   Auto selects based on type of load unit senses and can also be set manually.  

• Lutron

R

 offers guaranteed compatibility with Lutron LED drivers when dimming

• Ecosystem

R

 and DALI load types (for ‘plus’ projects)

  – Fixture by fixture control
  – Lights track together, not dependent on which 0–10 driver being used
  – Extensive driver and lamp feedback
  – Digitally addressable fixtures can be wired without regard to zoning
  – Alerts and alarms for facility maintenance 
•  RTISS technology provides stable phase control dimming under industry widest range of common noise types 

found in hotels. 

 

Advanced sensor technology

•  Available in multiple form factors
•  Enhanced with XCT

T

 technology for increased sensitivity

•  Easy installation with guaranteed 10 year battery life

 

Lutron

R

 Clear Connect

R

 Wireless Technology:

• Lutron

R

 uses Clear Connect

R

 for RF communications. Clear Connect

R

 operates in a protected frequency 

band (434MHz in the US, 868MHz in Europe) and avoids the crowded 2.4GHz band of many competing 

technologies. This ensures trouble free communications and an excellent experience for the guest – the 

controls work the first time, every time. 

•  Using Clear Connect

R

, Lutron

R

 offers wireless sensors and controls. These devices all have a 10 year battery 

life. Being wireless, these devices allow for easy mounting, installation, and relocation. 

  Lutron Guest Presence Detection for energy savings

•  A very important feature of the myRoom

T

 system – in either prime or plus – is guest presence detection. By 

combining door open / close, occupancy sensor and button press information in the space, the system knows 

when a guest is in the space, versus when everyone has left the space. If a guest is present in the space, the 

system turns over control to the guest – never again have your sleeping guest wake up because the thermostat 

sensor in the room stopped seeing him. 

  Shading Systems: 

•  Access to many preset stopping positions – more than open / close / stop.
•  Ultra quiet low-voltage electronic drive units.  
•  Roller shades have intelligent hembar alignment to maintain a clean façade
•  Direct connection from controllers / keypads to shades reduces number of devices to design, install, program 

and maintain. 

•  Pull to start functionality with draperies are intuitive for the guest

Summary of Contents for myRoom

Page 1: ...myRoomTM Operations and Maintenance MANUAL...

Page 2: ...nstructions Associated with the System and its Components 5 Section 4 myRoomT One line Diagrams 6 Section 5 Procedure myRoomT System Overview 8 Section 6 myRoomT On Site System Pre Wire Startup and Tr...

Page 3: ...our world headquarters at 1 610 282 3800 Thank you again for your purchase and we hope that you enjoy your new myRoomT Guestroom Control System Why LutronR Global company with local offices support t...

Page 4: ...ConnectR operates in a protected frequency band 434MHz in the US 868MHz in Europe and avoids the crowded 2 4GHz band of many competing technologies This ensures trouble free communications and an exce...

Page 5: ...am lutron com South American S o Paulo Brazil Lutron BZ do Brasil Ltda TEL 55 11 3257 6745 sabrasil lutron com International Offices China Beijing TEL 86 10 5877 1818 China Guangzhou TEL 86 20 2885 88...

Page 6: ...training on and knowledge of LutronR guestroom controls equipment should be permitted to perform maintenance on this equipment Always de energize lockout tagout and verify de energized all electrical...

Page 7: ...PELV NECR Class 2 24 V 132 mA 4 4 in lb 0 5 N m 65 75 C Cu Al N N N N N N M L L myRoomTM MQSE 4A1 D 100 240 V 50 60 Hz 4 A 1 610 282 3800 lutron com 24 V COM MUX MUX Zn 1 Prog Zn 2 Zn 3 Zn 4 IEC PELV...

Page 8: ...cal System Example myRoomTM Plus Guestroom Control Unit Hotel Network Property Management System PMS Lutron Property Management System PMS Interface Software Building Management System BMS Room Thermo...

Page 9: ...ill be programmed with default values or as noted in the attached zone schedule Keypad buttons will control lighting loads and automated shades in the guest room when pressed 230V Thermostat One piece...

Page 10: ...essary to put unrented rooms into a deep energy saving mode This is done with a temperature setback all lighting off and drapes closed The LutronR system receives this information from the hotel s PMS...

Page 11: ...utronR guestroom control system database This service is typically required when programming information was not provided to LutronR prior to the shipping the system devices or when the customer reque...

Page 12: ...damage the equipment and void the warranty Sensors No maintenance required DIN Processor Power Panels Visually inspect installation periodically Keep airflow clear of obstructions DIN Power Panels ge...

Page 13: ...packaging Example QSE IO U S A Canada and the Caribbean 1 800 523 9466 Other countries call 1 610 282 3800 Fax 1 610 282 1243 Visit us on the web at www lutron com Lutron Electronics Co Inc 7200 Sute...

Reviews: