background image

Maestro

®

Sensor

369741a 1  11.15.12

®

S P E C I F I C AT I O N   S U B M I T TA L

Page

Job Name:

Job Number:

Model Numbers:

Switch with Occupancy/ Vacancy Sensor

Maestro

®

 Occupancy sensing switch

To power the sensing circuit, occupancy sensing switches require a small flow of 

current when the load is in the OFF state. This can be accomplished by connecting the 

power supply return wire to ground or to neutral.
Local codes in certain municipalities require that a neutral conductor be run to the 

switch box, regardless of construction. In one particular instance, installing occupancy 

sensors that use the ground wire to function is not permitted.
The MS-OPS6M2U-DV and MS-VPS6M2U products allow the installer to configure the 

device to connect to either ground or neutral.

•  To connect to ground, simply install the product in its "out-of-the box" condition.
•  To connect to neutral, install the supplied white sleeve over the green wire.

For more information about occupancy sensing switches and the National Electrical 

code, see:

www.lutron.com/TechnicalDocumentLibrary/048469.pdf

Features

•  Passive infrared sensors with exclusive Lutron

®

 XCT

TM

 Technology for fine motion 

detection

•  180° sensor field-of-view
•  Up to 30 ft x 30 ft (9 m x 9 m) [900 ft

2

 (81 m

2

)] major motion coverage and 

 

20 ft x 20 ft (6 m x 6 m) [400 ft

2

 (36 m

2

)] minor motion coverage

•  Occupancy version can be set to Auto-ON / Auto-OFF or Manual-ON / Auto-OFF
•  Vacancy version available to meet CA Title 24 requirements
•  Adjustable timeout (1, 5, 15, or 30 minutes) and high/low sensitivity adjustment
•  Occupancy sensing switch loads: incandescent, halogen, ELV, MLV, CFL, LED, magnetic fluorescent, electronic 

fluorescent, and fan.

Models available

MS-OPS6M2U-DV
 MS-VPS6M2U-DV

MS-OPS6M2U-DV
MS-VPS6M2U-DV