Lutron Electronics LUT-ELI-3PH Instruction Manual Download Page 6

NEC

®

 Class 2/PELV Wiring Example:

LCP128

®

 and Softswitch128

®

 (XPS) Panels

´FACP´ N/C

CONTACTS

´FACP´ N/O

CONTACTS

CLASS 2 LOW VOLTAGE WIRING

GN

D

SENSE

D

R

A

I

N

MUX

MUX

+24VFW

COMMON

NOT USED

LE

D

1

LE

D

3

LE

D

2

RADIOTOUCH

PHASE

FACF

S1

TEST

1

2
3,4

5

1

2

3,4

1 2 3 4D5

1 2 3 4

1 2 3 4D5

1 2 3 4

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

6

5

4

3

2

1

Panel 1  

Panel 2  

Shield/Drain  

To lighting controls  
or processors  

Sense:

(1) 18 AWG  
(1.0 mm

2

)

5: Sense line  

Data Link:  
(1) shielded,  
twisted pair  
18 AWG  
(1.0 mm

2

3: MUX 

4: MUX  

Control Wiring:
(2) 12 AWG
(2.5 mm

2

)

1: Common

2: 24 V

Rasterized

•  One LUT-ELI-3PH unit may be connected in parallel with up to 32 LCP/XPS 

controllers. 

•  LUT-ELI-3PH unit may be placed anywhere on the power panel link. 
•  Switch position SW6 on the controller must be in the right-most position, ‘(Essential)’ 

on all Emergency Panels.

•  The LUT-ELI-3PH unit 24 V

Rasterized

  input must always be connected to at least one of 

the Emergency Panels.

S P E C I F I C AT I O N   S U b M I T TA L

Page

Job Name:

Job Number:

Model Numbers:

LUTRON

®

LUT-ELI-3PH

Power Accessories

P/N 369-299B    6   11.11.10                

6

Summary of Contents for LUT-ELI-3PH

Page 1: ...nel circuit selector controller EcoSystem bus supply Energi Savr Node unit GRAFIK Eye QS system or Quantum bus supply with emergency essential power causing it to enter the emergency lighting mode Any...

Page 2: ...ight Status light indicates the phase status Status light ON is normal mode OFF is emergency mode Test Button A test button is provided to perform a functional test of the system by simulating an emer...

Page 3: ...FW COMMON NOT USED LED1 LED3 LED2 RADIOTOUCH PHASE FACF S1 TEST 2 50 in 63 5 mm 4 x 4 in 102 x 102 mm Junction Box For line voltage wiring only Mounting Example Side View Cross Section Insert NEC Clas...

Page 4: ...3 Phase Diagram Single Phase Diagram Normal Power Normal Power Ground Neutral Hot Red Red White Green Guide to Power Source Wiring Red FACP N C CONTACTS FACP N O CONTACTS 12 11 10 9 8 7 6 5 4 3 2 1 CL...

Page 5: ...Sense 1 18 AWG 1 0 mm2 5 Sense line To lighting controls NEC Class 2 PELV Wiring Example GRAFIK Systems GP XP and LP Panels One LUT ELI 3PH unit may be connected in parallel with up to 32 circuit sel...

Page 6: ...Sense line Data Link 1 shielded twisted pair 18 AWG 1 0 mm2 3 MUX 4 MUX Control Wiring 2 12 AWG 2 5 mm2 1 Common 2 24 V Rasterized One LUT ELI 3PH unit may be connected in parallel with up to 32 LCP X...

Page 7: ...onsulte la Gu a de Instaladores para informaci n m s detallada R f rer au Guide d installation pour plus de renseignements d taill s 120 277 V 60 Hz 16 A Max 0 10 V Red black Rojo Negro Rouge Noir Rad...

Page 8: ...T ELI 3PH unit trips the EcoSystem bus supply stops powering the EcoSystem bus and all ballasts will turn on to their emergency light level Note The LUT ELI 3PH unit includes 2 Fire Alarm Control Pane...

Page 9: ...it terminal 7 Circuit Common and to Energi Savr Node Com terminal of Emergency Contact Closure Input Wire Signal wire from LUT ELI 3PH unit terminal 1 to Energi Savr Node Emerg terminal of Emergency C...

Page 10: ...ne LUT ELI 3PH unit Wiring Summary Wire power pack red wire 24 V to LUT ELI 3PH unit terminal 8 VFW Wire power pack black wire Common to LUT ELI 3PH unit terminal 7 Common and to Quantum bus supply te...

Page 11: ...Unit FACP N O CONTACTS TAGE WIRING GND SENSE NOT USED LED1 LED3 LED2 RADIOTOUCH PHASE FACF S1 TEST 12 9 8 7 6 5 4 3 2 1 FACP CP N O C C ONTACTS TAGE WIRING SENSE NOT USED LED RADIOTOUCH 12 8 7 6 5 4 3...

Page 12: ...ode Once the contact is released the LUT ELI 3PH unit will return the GRAFIK Systems GP LP XP panel s XPS LCP RadioTouch controller EcoSystem Bus Supply GRAFIK Eye QS unit or Quantum Bus Supply back t...

Reviews: