![background image](http://html1.mh-extra.com/html/lutron-electronics/ll-intmount/ll-intmount_integration-manual_1951095001.webp)
Limelight by Lutron OEM Integration Guide
Integration Guide
P/N 041664 Rev. D
01/2019
1
Customer Assistance: 1.844.LUTRON1
(1.844.588.7661)
This document is intended for luminaire/fixture manufacturers who are integrating Limelight by Lutron
LL-INTMOUNT and LL-PIR-L/M/H modules into their luminaires. It provides recommendations for electrical and
mechanical integration of these modules into a luminaire, and recommended manufacturing test procedures.
1. Standards
•
RoHS Compliant
•
FCC15.247 / IC RSS-247
(LL-INTMOUNT)
•
cULus Recognized for internal mounting at a fixture OEM
•
IP66 (wet locations) (LL-PIR-L/M/H) when lens assembly is installed correctly at fixture manufacturer
2. Model Numbers
Model Number
Description
LL-INTMOUNT
Limelight by Lutron Radio Module PCB Assembly
LL-PIR-L
Limelight by Lutron PIR Sensor Assembly; for 8 to 15 ft (2.5 to 4.6 m) mounting height
LL-PIR-M
Limelight by Lutron PIR Sensor Assembly; for 16 to 30 ft (4.9 to 9 m) mounting height
LL-PIR-H
Limelight by Lutron PIR Sensor Assembly; for 31 to 40 ft (9.5 to 12 m) mounting height
3. LL-INTMOUNT Integration
Mechanical Integration
Dimensions shown as: in (mm)
The LL-INTMOUNT module has multiple holes (diameter = 0.11 in [2.75 mm]) for mounting to a luminaire. The
LL-INTMOUNT should be mounted using a minimum of two of the holes to ensure that the PCB does not
excessively vibrate.
The LL-INTMOUNT should be mounted in a location that is not accessible by the user because parts of the
PCB have a high-voltage and should be out of reach.
The LL-INTMOUNT should be mounted as far away from metal housings and components as possible.
Top View
Bottom View
Tallest component
approx. 0.8 (20.3)
Tallest
component
approx. 0.16 (4)
2.69 (68.3)
1.12 (28.5)
1.12 (28.5)
1.12 (28.5)
1.12 (28.5)
1.24 (31.4)
0.57 (14.5)
0.19 (4.8)
0.57 (14.5)
0.57 (14.5)
0.24 (6.19)
0.24 (6.19)
0.57 (14.5)
0.829 (21)
Ø2.751
(Ø69.9)
Holes
Ø2.751 (Ø69.9)
Clearance areas
both sides of PCB
Ø0.23 (Ø5.84)
Solder mask is not relieved around
holes. If using metal fasteners,
plastic washers/spacers must
be used.
Preferred mounting hole