background image

Limelight by Lutron OEM Integration Guide

Integration Guide

P/N 041664  Rev. D

01/2019

1

Customer Assistance: 1.844.LUTRON1

 (1.844.588.7661)

This document is intended for luminaire/fixture manufacturers who are integrating Limelight by Lutron 

LL-INTMOUNT and LL-PIR-L/M/H modules into their luminaires. It provides recommendations for electrical and 

mechanical integration of these modules into a luminaire, and recommended manufacturing test procedures.

1. Standards

 •

  RoHS Compliant

 •

    FCC15.247 / IC  RSS-247

 

(LL-INTMOUNT)

 •

  cULus Recognized for internal mounting at a fixture OEM 

 •

  IP66 (wet locations) (LL-PIR-L/M/H) when lens assembly is installed correctly at fixture manufacturer

2. Model Numbers

Model Number

Description

LL-INTMOUNT

Limelight by Lutron Radio Module PCB Assembly

LL-PIR-L

Limelight by Lutron PIR Sensor Assembly; for 8 to 15 ft (2.5 to 4.6 m) mounting height

LL-PIR-M

Limelight by Lutron PIR Sensor Assembly; for 16 to 30 ft (4.9 to 9 m) mounting height

LL-PIR-H

Limelight by Lutron PIR Sensor Assembly; for 31 to 40 ft (9.5 to 12 m) mounting height 

3. LL-INTMOUNT Integration

Mechanical Integration

Dimensions shown as: in (mm)

The LL-INTMOUNT module has multiple holes (diameter = 0.11 in [2.75 mm]) for mounting to a luminaire. The 

LL-INTMOUNT should be mounted using a minimum of two of the holes to ensure that the PCB does not 

excessively vibrate.
The LL-INTMOUNT should be mounted in a location that is not accessible by the user because parts of the 

PCB have a high-voltage and should be out of reach.
The LL-INTMOUNT should be mounted as far away from metal housings and components as possible.

Top View

Bottom View

Tallest component 

approx. 0.8 (20.3)

Tallest 

component 

approx. 0.16 (4)

2.69 (68.3)

1.12 (28.5)

1.12 (28.5)

1.12 (28.5)

1.12 (28.5)

1.24 (31.4)

0.57 (14.5)

0.19 (4.8)

0.57 (14.5)

0.57 (14.5)

0.24 (6.19)

0.24 (6.19)

0.57 (14.5)

0.829 (21)

Ø2.751 
(Ø69.9)

Holes 
Ø2.751 (Ø69.9)

Clearance areas 
both sides of PCB 
Ø0.23 (Ø5.84)

Solder mask is not relieved around 

holes. If using metal fasteners, 

plastic washers/spacers must  

be used.

Preferred mounting hole

Preferred mounting hole

Summary of Contents for LL-INTMOUNT

Page 1: ...0 ft 4 9 to 9 m mounting height LL PIR H Limelight by Lutron PIR Sensor Assembly for 31 to 40 ft 9 5 to 12 m mounting height 3 LL INTMOUNT Integration Mechanical Integration Dimensions shown as in mm...

Page 2: ...tor slots For stranded wires press down on the button next to each connector slot to allow wire entry Releasing the button will cause the connector to grip the wire Wire Gauge 16 20 AWG 1 5 0 5 mm2 Th...

Page 3: ...le fixture for further RF testing If a sample is requested the required performance testing may take up to 3 weeks starting from when the sample is received by Lutron For best RF performance of the LL...

Page 4: ...erproof and should not be mounted in a location where it will receive direct contact with water It is however conformal coated and can withstand humid or moist conditions Regulatory Labelling Requirem...

Page 5: ...to properly engage the internal seal 3 Visually inspect to verify plastic PIR lens assembly is seated properly and not tilted relative to the fixture Tilting could possibly imply cross threading whic...

Page 6: ...it is commissioned correctly Luminaire Power Up Timing When the LL INTMOUNT powers up it cycles the luminaire through various states so the manufacturer can determine if the luminaire has been wired...

Page 7: ...bbean 1 800 523 9466 Mexico 1 888 235 2910 Central South America 1 610 282 6701 EUROPEAN HEADQUARTERS United Kingdom Lutron EA Ltd 6 Sovereign Close London E1W 3JF United Kingdom TEL 44 0 20 7702 0657...

Page 8: ...tage de 4 9 9 m 16 30 pi LL PIR H Ensemble de d tecteur PIR de Limelight par Lutron pour une hauteur de montage de 9 5 12 m 31 40 pi 3 Int gration de LL INTMOUNT Int gration m canique Dimensions repr...

Page 9: ...ton permet au connecteur de saisir le fil Diam tre de fil 1 5 0 5 mm2 16 20 AWG Le connecteur 5 broches peut accepter des diam tres de fil de 1 5 0 5 mm2 16 20 AWG Longueur du c ble d nud 8 9 mm 0 3 0...

Page 10: ...re for further RF testing If a sample is requested the required performance testing may take up to 3 weeks starting from when the sample is received by Lutron For best RF performance of the LL INTMOUN...

Page 11: ...25 5 mm 1 po du LL INTMOUNT Le LL INTMOUNT n est pas tanche et ne doit pas tre mont dans un endroit o il sera en contact direct avec de l eau Toutefois il poss de un rev tement enrobant et peut r sist...

Page 12: ...cher correctement le joint interne 3 Inspectez visuellement pour v rifier que la lentille du PIR en plastique est correctement install e et n est pas inclin e par rapport au luminaire Une inclinaison...

Page 13: ...de mise sous tension du luminaire Lorsque le LL INTMOUNT s allume il fait passer le luminaire par diff rents tats pour permettre au fabricant de d terminer si le luminaire a t c bl correctement La s q...

Page 14: ...ue du Nord et du Sud tats Unis Canada Cara bes 1 800 523 9466 Mexique 1 888 235 2910 Am rique Centrale du Sud 1 610 282 6701 SI GE EUROP EN Royaume Uni Lutron EA Ltd 6 Sovereign Close London E1W 3JF R...

Reviews: