background image

Hi-lume Premier 0.1% Constant Voltage Driver (L3D0)

®

S P E C I F I C AT I O N   S U B M I T TA L

Page

Job Name:

Job Number:

Model Numbers:

LED Dimming Driver

Architectural Dimming

369883d   5   04.19.17

50016452a

lutron.com

0 784276 166027

120 - 277 V      50 / 6

0 Hz   0,92 - 0,40 A   1

10 W Max

Soft-on, Fade-to-Black

TM

EcoSystem

TM

 3-wire Constant Volta

ge LED Driver

LED Driver 4RM5

L3D0-96W24V-U

Allumage doux, fondu 

au noir

EcoSystem

TM

Pilote 3-fil tension co

nstante pour DEL

USA / Canada: 1.844

.LUTRON1 (1.844.58

8.7661)

Input | Entrée:

Output | Sortie:

24 V      4 A Max   Cla

ss 2

B2

Warranty void if inner 

plastic cover is remov

ed.

Garantie annulée si le

 couvercle plastique in

térieur est ouvert.

Field Adjustment Kno

b

Bouton de Réglage po

ur utilisation en chantie

r

Hi-lume

®

Premier 0.1%

Suitable for damp loca

tions.

Convient aux emplace

ments humides.

Use 20 - 12 AWG wire

 only.

Utiliser un fil de 0,50 

- 2,5 mm² seulement

.

WARNING:

 Shock hazard. May re

sult in serious injury o

r death. 

Disconnect power befo

re opening top lid, servicing or installing.

AVERTISSEMENT

 :

 Danger d'électrocutio

n. Peut causer de grav

es

lésions ou le décès de

 la personne. Couper l

’alimentation du

disjoncteur avant de p

rocéder à l’ouverture d

e couvercle supérieur,

au montage ou à l’entr

etien de l’installation.

Pats | Brevets: 7,911,1

56

Lid screws: 8-32 x 3/8

” thread-rolling, serrate

d

Vis du couvercle: 8-32

 x 3/8” roulage de filets

, dentelées

1/4 in (6,5 mm)

Cu Al

Enclosure Dimensions

Measurements are shown as: in (mm)

Knockouts

• Sides 

– 4 locations: 1/2 in or 21 mm trade size

• Top 

– 2 locations: 1/2 in or 21 mm trade size

10.5 (267)

2.0 (51)

5.5 (140)

5

Summary of Contents for L3D0-96W24V-U

Page 1: ...with EcoSystem controls PowPak with EcoSystem dimming modules PowPak with EcoSystem wireless fixture controls and Quantum systems allowing for integration into a planned or existing EcoSystem lightin...

Page 2: ...stant voltage at high end Output Load Range 2 W to 96 W at high end PWM dimming frequency meets IEEE1789 at all dim levels Power Factor 0 90 at maximum power Total Harmonic Distortion THD 20 at maximu...

Page 3: ...o 12 AWG 0 50 mm2 to 2 5 mm2 Maximum wire length between the LED driver and the start of the linear strip for different wire sizes is listed below The table below can be used independently of the line...

Page 4: ...Specifications are subject to change without notice Output Voltage vs Output Power Output Power W Output Power W Output Power W Output Voltage V THD Efficiency 0 0 10 10 20 20 30 30 40 40 50 50 60 60...

Page 5: ...on de R glage pour utilisation en chantier Hi lume Premier 0 1 Suitable for damp locations Convient aux emplacements humides Use 20 12 AWG wire only Utiliser un fil de 0 50 2 5 mm seulement WARNING Sh...

Page 6: ...tural Dimming 369883d 6 04 19 17 Mounting Options1 2 1 Any other mounting configuration will require additional mechanical support Improper installation may result in hazards to personnel or property...

Page 7: ...EcoSystem links are wired as Class 2 or between the EcoSystem control and output terminals Option 2 when the EcoSystem links are wired as Class 1 For 3 wire control barrier could be placed in either l...

Page 8: ...M5 Hi lume Premier 0 1 WARNING Shock hazard May result in serious injury or death Disconnect power before opening top lid servicing or installing AVERTISSEMENT Danger d lectrocution Peut causer de gra...

Page 9: ...14 Maestro Wireless dimmer MRF2 F6AN DV 1 6 1 14 RadioRA 2 dimmer RRD F6AN DV 1 6 1 14 Dual voltage 3 wire dimmer 21 4 HomeWorks QS dimmer HQRD F6AN DV 1 6 1 14 Fluorescent 3 wire LED 3 wire 21 4 Inte...

Page 10: ...EcoSystem link GRAFIK Eye QS unit with EcoSystem QSGRJ _E QSGR _E 9 009 or higher 64 per EcoSystem link Quantum Light Management Hub QP2 _P_C 3 2 or higher4 64 per EcoSystem link HomeWorks QS with Ec...

Page 11: ...ase consult load manufacturer best practices for any additional consideration in load installation When connecting several LED light homeruns ensure that the wire lengths and wattages match as closely...

Page 12: ...r wire per terminal Make sure that the supply breaker to the drivers and EcoSystem Digital Link Supply is OFF when wiring E1 and E2 terminals of the drivers can be daisy chained as shown to the right...

Page 13: ...ustment Knob cannot fix light level mismatch among loads on the same driver For example two homeruns of different wattage For increasing the minimum light output of all the drivers in a space please u...

Page 14: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is...