3-1  Platform 

3-2  CAL. Button ( function A Button ) 

3-3  Tare Button ( function B Button ) 

3-4  Display 

3-5  Power Switch 

3-6  Rubber Pads 

3-7  Battery Cover/Compartment 

3-8  DC 9V Receptacle 

3-9  RS232 Output Socket 

3-10 Unit Switch 

 

 

4. PLATFORM INSTALLATION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 2 

Summary of Contents for GM-1500P

Page 1: ...CE marks a step forward for you into the field of precision measurement Although this DIGITAL BALANCE is a complex and delicate instrument its durable structure developed Please read the following ins...

Page 2: ...3 3 4 Display 3 3 5 Power Switch 3 3 6 Rubber Pads 3 3 7 Battery Cover Compartment 3 3 8 DC 9V Receptacle 3 3 9 RS232 Output Socket 3 3 10 Unit Switch 3 4 PLATFORM INSTALLATION 4 5 WEIGHT MEASURING PR...

Page 3: ...rcuit permanently even power off High precision counting scale function RS 232 computer interface Accept battery or AC DC adapter power source two way power supply Built in level bubble the adjustable...

Page 4: ...t Microprocessor circuit Auto Calibration Use 500 g or 1000 g standard weight to execute self calibration automatically Operating Temperature 0 to 50 32 to 122 Operating Humidity Less than 80 RH Size...

Page 5: ...3 3 FRONT PANEL DESCRIPTION Fig 1...

Page 6: ...utton function A Button 3 3 Tare Button function B Button 3 4 Display 3 5 Power Switch 3 6 Rubber Pads 3 7 Battery Cover Compartment 3 8 DC 9V Receptacle 3 9 RS232 Output Socket 3 10 Unit Switch 4 PLA...

Page 7: ...e left position will set to oz unit but the LCD display will not show any marker 3 Turn the Power Switch 3 5 Fig 1 to the On position 1 On 0 Off The Display 3 4 Fig 1 will show 8 8 8 8 8 for a few sec...

Page 8: ...on again 6 SELF CALIBRATION 1 Please prepare the following optional Standard Weight 500 gram standard weight optional or 1000 gram standard weight optional 2 Calibration under the 1000 gram standard w...

Page 9: ...nce again display value of 500 00 g will flash 6 times then the calibration procedures are finished completely balance is ready for the measurement accurately Consideration of Self Calibration The int...

Page 10: ...e finger away from function A Button 3 Step 2 Push the function A Button 3 2 Fig 1 once a while again then the bottom left corner of LCD will show the COUNT marker At the same time the LCD will show n...

Page 11: ...ice and freeze the set counting no then take away the sample units Now the balance is ready for counting the sample counting units already change to new value Consideration Under the counting function...

Page 12: ...mpartment replace the battery cover 9 DC 9V AC DC ADAPTER OPERATION Adapter is optional accessory 1 The scale will also be operated by the household ACV power source 110 220 240 ACV with a DC 9V AC DC...

Page 13: ...the PC serial input The 16 digit data stream will be displayed in the following format Each digit indicate the following status D0 End Word D1 D8 Display reading D1 LSD D8 MSD For example If the displ...