DC Current, AC Current ( True RMS )
DC Current, AC Current ( True RMS )
DC Current, AC Current ( True RMS )
DC Current, AC Current ( True RMS )
Range
10 A/6 A/600 mA/60 mA/6000 uA/600 uA
Resolution
0.01 A/0.001 A/0.1 mA/0.01 mA/1 uA/0.1 uA
Accuracy
DCA
ACA
600 uA
± ( 0.5 % + 2d )
± ( 1 % + 7d )
6000 uA
± ( 0.5 % + 2d )
± ( 1 % + 7d )
60 mA
± ( 0.5 % + 2d )
± ( 1 % + 7d )
600 mA
± ( 0.5 % + 2d )
± ( 1 % + 7d )
6 A
± ( 1.5 % + 5d )
± ( 1.5 % + 5d )
10 A
± ( 1.5 % + 2d )
± ( 1.5 % + 2d )
* ACA spec. are tested under 50/60 Hz.
Over load
10A range : 10A / 600V fuse.
protection
uA, mA range : 600 mA / 600V fuse.
Diode ( Forward voltage, VF )
Diode ( Forward voltage, VF )
Diode ( Forward voltage, VF )
Diode ( Forward voltage, VF )
Range
2.9 V DC.
Accuracy
±( 0.5% + 2d )
Capacitance
Capacitance
Capacitance
Capacitance
Auto Range
600 pF/6 nF/60 nF/600 nF/6 uF/60 uF/100 uF/600 uF
Resolution
0.1 pF/0.001 nF/0.01nF/0.1 nF/0.001 uF/0.01 uF/0.1 uF/1uF
600 pF
±( 2.5% + 5d )
Accuracy
6 nF/60 nF/600 nF/6 uF/60 uF
±( 1.5% + 5d )
100uF/600 uF
±( 5% + 5d )
Test frequency
100Hz /1KHz /10KHz
(Auto frequency configuration)
Remark
Discharge capacitor before testing.
Over load protection
±30 DCV, 30 ACV.
Inductance
Inductance
Inductance
Inductance
Auto Range
600 uH/6 mH/60 mH/600 mH/6 H/60 H/100 H
Resolution
0.1uH/0.001mH/0.01 mH/0.1 mH/0.001 H/0.01 H/0.1 H
Test frequency
100Hz /1KHz /10KHz
(Auto frequency configuration)
600 uH
±( 5% + 5d )
Accuracy
6 mH/60 mH/600 mH/6 H
±( 1.5% + 5d )
60 H/100 H
±( 2.5% + 5d )
Over load protection
±30 DCV, 30 ACV.