b. Turn headlight switch on.

Turn high beam switch on.
Turn ignition switch on.
Turn heater switch on.
Turn radio on.

c. Do not continue above procedures for more than 2

minutes 

d. Check that display reading is greater than 11.7 volts.  If

reading is not correct, battery should be charged or
replaced.

8) APPLICATION 4 : to check the " BATTERY

CAPACITY " (Used the DC 200V or 20V range)
a. Disconnect " HIGH TENSION WIRE " from

distribution cap. & ground " HIGH TENSION WIRE "
by laying or taping lug to bare metal surface.

b. Connect BLACK TEST PROBE to NEG (-) battery

terminal,  Connect RED TEST PROBE to POS (+)
battery terminal.

c. After cranking engine for about 15 seconds, check the

display reading is greater than 9.1 volts.  If reading is
not correct, start motor should be checked or battery
should the charged or replaced.

9) APPLICATION 5 : to check the " BATTERY CABLE " :

(Used the DC 2V range). Measure the across voltage of 
" BATTERY CABLE " when cranking the engine to check
the condition of " BATTERY CABLE "

   10)OTHER DCV RANGE APPLICATION :

a. Check Charging System.
b. Check Voltage Regulator. 

Summary of Contents for DM-9030

Page 1: ......

Page 2: ...minal 1 3 7 Battery compartment 1 4 PRECAUTIONS PREPARATIONS FOR MEASUREMENT 1 5 MEASURING PROCEDURE 5 1 Voltage Measurement 1 5 2 Current Measurement 1 5 3 Resistance Measurement 1 5 4 Temperature Me...

Page 3: ...tion Do not apply the overload voltage current to the input terminal Remove test leads before open the battery cover Environment Conditions Installation categories II Pollution Degree 2 Altitude up to...

Page 4: ...e range of automotive electronics tests Duty cycle with Dwell conversion chart for electronic fuel injection and feedback carburetors Diode test quickly measures the forward bias voltage drop of alter...

Page 5: ...olarity Zero Adjustment Automatic Over input Display shows 1 or 1 Sampling time Approx 0 4 second Operating Temp 0 to 50 32 to 122 Operating Less than 80 RH Humidity Power Approx DC 3 6 mA Consumption...

Page 6: ......

Page 7: ...emove either of the test leads from the circuit under test when changing the measurement range 6 Operate the instrument only in the ambient temperature range of 32 122 0 50 and less than 80 relative h...

Page 8: ...LOW voltage value should under 1 V If not bump engine until it reach d If the above c point voltage display showed lower than 0 2V then the contact resistance of Points is normal or it need to be cha...

Page 9: ...ground HIGH TENSION WIRE by laying or taping lug to bare metal surface b Connect BLACK TEST PROBE to NEG battery terminal Connect RED TEST PROBE to POS battery terminal c After cranking engine for ab...

Page 10: ...measured 5 3 Resistance Measurement 1 Connect red test lead to OHM input terminal and black test lead to COM input terminal 2 Determine the highest anticipated resistance 200OHM 2K 20K 200K 2000K or...

Page 11: ...n device if greatest accuracy is to be achieved This will only take a couple of minutes and only applies if the plug of probe has previously been exposed to an ambient temperature different ot that me...

Page 12: ...o 3 SPARK PLUG ref Fig 2 then the display will show RPM reading x 10 RPM NOTE a RPM TACH used the Secondary Tech measuring method no matter what cylinder is b If the display reading is unstable it may...

Page 13: ...minal 3 Connect red test probe into BREAKER POINTS or terminal of IGNITION COIL Connect black test probe into GROUND or terminal of battery The wire connection diagram please ref fig 3 4 Crank engine...

Page 14: ...nto circuit under test If the resistance value to f the circuit is less than approx 100 OHM then there will be Beeper sound output from the meter A When connected with polarity as shown in Fig 4 a for...

Page 15: ...ENT PROBE This range is exactly same as DC 2V range but without decimal point It can match the 400 A or 2 000 A range of optional DC AC CURRENT PROBE such as CA 501 CA 202 then can get current values...

Page 16: ...thermocouple suitable for many general purpose application Temperature Probe Measure Range 50 to 900 Type K TP 02A 50 to 1700 Dimension 10cm tube 3 2mm dia Temperature Probe General purpose applicati...

Page 17: ...The address of after service center 9610 DM 9030 IEC1010...