5-4 Temperature Measurement
1) Insert the plug of the Thermocouple Probe (optional)
into the " Temperature Probe Socket " ( 3-5, fig 1 ) , take
care to observe the correct polarity.
2) Determine the
蚓
or
蚌
on the " Function Switch " and
select to the corresponding position.
3)
Consideration:
When the Thermocouple Probe is first plugged into the
meter, or if the probe is changed, the plug must be
allowed to stabilize at the same temperature of the
socket, which is in thermal contact with the cold junction
compensation device, if greatest accuracy is to be
achieved. This will only take a couple of minutes and
only applies if the plug of probe has previously been
exposed to an ambient temperature different ot that
meter.
5-5 Frequency Measurement
1) Connect black test lead to " COM " terminal and red test
lead into "Hz" terminal.
2) Determine the highest anticipated frequency ( 200 Hz, 2K
Hz 20K Hz) on the " Function Switch " and select to its
corresponding position.
3) Connect test lead probes into circuit under test.
5-6 "RPM (TACH.)" Measurement
1) RPM measurement is with INDUCTIVE PICKUP
SENSOR, IP-07 (Optional).
2) Connect above INDUCTIVE PICK UP Sensor's black
test lead into " COM " terminal and red test lead into
" TACH " terminal.