5.3.2 Sensor Setup
Item
Description
Alarm Duration(Seconds)
This is the record time in sec. after a motion detection occured.
Within this time no other motion event can be detected.
Sensor Popup
Check the box to Enable/Disable popup screen function for all channels.
When Sensor is detected in LIVE mode, the detected channel image will
pop up in full screen display.
Sensor Polarity
Click or press
▼ to select between HIGH/ LOW
voltage for triggering
sensor detection or OFF to turn off polarity for each channel
Low
Polarity
:
Sensor has not been triggered. When connected, sensor
will be turned on (N.O.
→N.C.).
High
Polarity
:
Sensor has been triggered. When connected, sensor
status will be turned off (N.C.
→N.O.).
Off
:
Sensor is deactivated, and will not be turned on/off.
All off
Set all sensors polarity to off.
All Low
Set all sensors p
olarity to low level.
All High
Set all sensors p
olarity to high level.
IMPORTANT: The Sensor input ports have got a potential of 5V. Hence, Sensor devices to be operated
with the LE800 D1 have to be potential-free. Use a two-pole cable to connect sensor device and
recorder. One pole has to be connected with one of the sensor input ports (4 ports are available), the
other pole has to be connected with the GND port.
IMPORTANT: To record at motion recognition, it is always necessary to activate a motion detection
schedule in the Main Menu „Schedule“. Please refer to chapter 5.4 for further instructions.