Electrical connections - Wiring diagrams
L
N
1
2
3
4
5
•
One-step operation, switchable to 60 m
3
/h
(Ventilator types ... 30/60)
5/W
Bridge
Bridge
5/W
Bridge
•
Two-step operation, switchable to 60 m
3
/h and 100 m
3
/h
ON/OFF
(Ventilator types ... 30/60)
5/W2
Bridge
5/W2
Bridge
Room illumination
Room illumination
Room illumination
•
Continuous operation 30 m
3
/h, switchable to 60m
3
/h or
100 m
3
/h
(Ventilator types ... 30/60)
•
Run-out time controlled 60 m
3
/h or 100 m
3
/h
(Ventilator types ... 60ZII; ... 100ZII)
•
Continuous operation 30 m
3
/h, with switchable run-out
time controlled 60m
3
/h or 100 m
3
/h
(Ventilator types ... 30/60ZII; ... 30/100ZII)
With movement detector
Note: For all circuits with movement detector
(Ventilator types … 60BZII; ... 100BZII; … 30/60BZII;
...30/100BZII;… 30/60B)
•
Three-step operation, continuous operation 30 m
3
/h,
switchable to 60 m
3
/h and 100 m
3
/h
(Ventilator types ... 30/60)
Note: Connection to light not possible
Two-room ventilator with run-out time:
•
Run-out time controlled 100 m
3
/h, switch-off in each of 2
rooms
(Ventilator types ...
100ZII)
•
Continuous operation 40 m
3
/h with run-out time controlled
100 m
3
/h, switch-off in each of 2 rooms
(Ventilator types ... 30/100ZII)
7
6
With remote control
(ventilator types ... F)
Note: Other circuits, e.g. via L1 or L2, are possible. Remote
control always has priority
0 ≤ 2 V:
>
2 ≤ 4 V:
>
4 ≤ 6 V:
>
6 ≤ 8 V:
>
8 ≤10 V:
>
10 ≤12 V:
Ventilator operation
acc. to switch position
Ventilator OFF
30 m³/h
40 m³/h
50 m³/h
60 m³/h
Room 1
60 m³/h
Room 2
40 m³/h
5/W
Bridge
5/W
Bridge
100 m
3
/h
(instead of L1
to L2) only
with ventilator
type 30/60)
Safety Precautions:
Caution! Carry out installation work on the ventilator only
when it is separated from the mains voltage! The ventilator
is protectively insulated according to protective class II,
the protective conductor connection is not needed.
Ensure that all connecting cables to the ventilator are
dead before connecting it! (Separate from the mains with
at least a 3 mm contact space, e.g. electric fuse).
Each circuit belonging to the ventilator must be equipped
with fault current protection (e.g. FI switch).
Electrical connection only by an electrician!
Additional installations and/or electrical components are not
permitted!
Wiring diagrams for further ventilator functions on request!