Filter change

 

• 

Continuous  red  light  up  of 
illuminated  display indicates 
a dirty filter 

• 

Take  of  the  front  cover 
plate,  remove  filter.  Insert 
new  or  cleaned  filter.  Dirty 
filters can be  cleaned,  e.g. 
in a washing machine. 

• 

Operate  button  for  3  sec-
onds with a pencil or similar 
to turn off the display illumi-
nation 

• 

Replace  the  front  cover 
plate 

 
Never operate the system 
without a filter!  

Illuminated 
display 

Button 

Front cover plate 

Grid cover frame 

Filter 

Run-out time setting:

 For ventilators with run-out time 5/ZII 

Caution! Only adjust the switch when ventilator is in the dead condition! 

 

Factory settings

 

:  

 

 

 
 

To change settings: 

1. Take the front cover plate off 
2. Draw the cap off of the electrics housing 
3. Make the wanted settings 
4. Re-assemble in the opposite succession

 

• 

Switch-on delay 120 sec 

• 

Run-out time 15 min 

• 

Inverse operation OFF 

• 

Interval switching OFF 

White toggle switch 

Remove cap with 
a screwdriver 

Electrics housing 

Cap  

Interval ON every 4 hrs for 30 min * 

Interval OFF 

Run-out time 15 min 

Run-out time 6 min 

Inverse operation 30 min after run-
down after the room is left * 

Inverse operation OFF 

Switch-on delay 120 sec 

Switch-on delay 0 sec 

Accessory and replacement parts 

Filter, pack of 3 

 

 

 

 

 

 

 

 

2/FSI-R  

Order no. 

039 721 

Silvento decor plate incl. filter display

 

 

 

 

 

 

 

 

 

2/S 

 

Order no. 

039 551 

Silvento decor plate with movement detector 

 

 

 

 

 

 

 

2/SB   

Order no. 

039 578 

 

Illuminated display         Button 

Ventilator with movement detector

Button and illuminated display are in the grid cover frame 

Ventilator with step switching, run-out time or 
humidity control:

 Button and illuminated display 

are in the electrics housing 

Cleaning

 

Wipe the front cover plate and grid cover frame with a dry, soft cloth when appropriate. 

Filter change and cleaning are not to be carried out by children or people who cannot manage this with certainty 
because of their physical, sensorial or mental ability, or their inexperience or lack of appropriate knowledge

 

 

* I

ndependent of the set  

   adjusted run-out time 

Summary of Contents for Skalar Series

Page 1: ...recautions and safety symbols with notes in the text must be observed When installation has been completed pass these directions on to the user renter owner block manager or other Symbols in these directions Danger Assembly work is only to be carried out on the ventilator when it is separated from the line voltage The ventilator is protectively insulated to protective class II the protective condu...

Page 2: ...with a Class G2 EN 779 filter and a filter change display Ventilators of the Silvento series fulfil all requirements of DIN 18017 3 Allgemeine Bauaufsichtliche Zulassung Z 51 1 215 for low voltage CE acc to EC Directives 2006 95 EG for electromagnetic compatibility CE acc to EC Directives 2004 108 EG Waste disposal Sort the packaging for appropriate disposal Observe current requirements should you...

Page 3: ...housings 260 mm 32 mm 69 mm 120 mm Grip 1 bis 42 mm Grip 2 ab 57 mm No grip possible bet ween 42 and 57 mm 25 5 mm 206 mm Flap valve Through the wall housing Caution Correct the flap valve position and seating if appropriate see page 5 Dimensional drawings Possible installation positioning for duct mounting ...

Page 4: ...lation in housing 3 LS or 3 LB 2 UP Clamped ventilators can replace all build in versions of the Skalar series These installation examples are therefore only a few of many possibilities Installation in housing 3 LB 2 room ventilator Installation in housing 3 LS Installation examples ...

Page 5: ... stick on 1a Check delivery for completeness and undamaged condition Filter Front cover plate Grid cover frame Ventilator insert for clamped ventilator Incl screws for connecting grid cover frame to ventilator insert Seal stick on when replacing a Skalar V Power supply terminal Sound insulation not with 2 room ventilators Slide nozzle with flap valve for rising building 1 Installation of clamped v...

Page 6: ...ng diagrams Caution The mains cable must be dead 2 Top view of power supply terminal L2 L1 L N F F Plug the power supply terminal on and latch on behind the notched hook 3 Lock the power supply terminal in behind the notched hook 4b Correct the flap valve position and seating important for ceiling installation In the installed condition the flap valve in the exhaust nozzle must close because of it...

Page 7: ...over frame and front cover plate according to the built in position of the ventilator 5 6 Flange bore holes 4 x Clamp Filter Front cover plate Grid cover frame Fitting the motion detector circuit board to the decor plate Plug the display board cable in Fasten the grid cover frame to the ventilator insert with the screws supplied and align it so that the cable lies under the motion detector circuit...

Page 8: ...pes 100ZII Continuous operation 40 m3 h with run out time controlled 100 m3 h switch off in each of 2 rooms Ventilator types 30 100ZII 7 6 With remote control ventilator types F Note Other circuits e g via L1 or L2 are possible Remote control always has priority 0 2 V 2 4 V 4 6 V 6 8 V 8 10 V 10 12 V Ventilator operation acc to switch position Ventilator OFF 30 m h 40 m h 50 m h 60 m h Room 1 60 m...

Page 9: ...x haust air volume flow to the room air humidity and room tempera ture it guarantees optimum comfort in the room to be ventilated In this way only as much ventilation as necessary but as little ventilation as possible is ensured and thus energy is saved The fan never switches off completely in order to ensure a minimum air change During summer months the increased exterior air hu midity does not m...

Page 10: ...ec Run out time 15 min Inverse operation OFF Interval switching OFF White toggle switch Remove cap with a screwdriver Electrics housing Cap Interval ON every 4 hrs for 30 min Interval OFF Run out time 15 min Run out time 6 min Inverse operation 30 min after run down after the room is left Inverse operation OFF Switch on delay 120 sec Switch on delay 0 sec Accessory and replacement parts Filter pac...

Reviews: