background image

 
© 2016, Lunatone Industrielle Elektronik GmbH 

 

                                                            DALI Display                       

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DALI Display 7” 

 

Quick Start Guide 

 Control Device 

 

 

 DALI Input- and Controldevice with 

7” Display and Touchpanel  

 

 

 

 

 

Version 1.0.6 

 

 

 

Summary of Contents for DALI

Page 1: ... 2016 Lunatone Industrielle Elektronik GmbH DALI Display DALI Display 7 Quick Start Guide Control Device DALI Input and Controldevice with 7 Display and Touchpanel Version 1 0 6 ...

Page 2: ...ign 12 4 2 Screensaver and Pincode Protection 13 4 3 Date and Time 14 4 4 Menu Bar 14 4 5 Site Numbering 14 5 Commissioning 15 5 1 Adressing Grouping 15 5 2 Scenes and Color Scenes 18 5 3 Sequence SQ day schedules SDL week schedules SDLL 23 5 4 Human Centric Lighting Circadian daylight progression 26 6 Ethernet Remote Control 27 7 System Update 31 8 Custom design 32 8 1 Photo of room with integrat...

Page 3: ...re considered the installation of the display must be performed by an qualified technician who can perform the required tasks and recognize potential danger due to professional training knowledge and experience in particular the knowledge of pertinent regulations and standards Touching the screen with sharp objects can result in damage of the display 1 3 Features The DALI Display has connectors fo...

Page 4: ...orted with the help of DALI Device Type 8 DT8 standard By naming groups scenes and automatic processes custom backgrounds and screen saver image the device can be individually adapted to the application Furthermore custom designed layouts are offered as a manufacturer service The display can be controlled via the 7 touch control panel but also via remote access through Ethernet and hence can be op...

Page 5: ...the DALI lines Therefore an external DALI power supply e g DALI PS has to be installed for each DALI line The DC power supply PS36V which is included in the delivery package is meant to supply the display only It is not suitable for the supply of a DALI Line Instead of using a PS36V the display can also be powered via POE typical installation ...

Page 6: ...nfiguration OFF Button Long Press Selection of effective range for OFF Cmd the setting is valid for any OFF Button and does not depend on active site Up from V1 0 6 the scheduler function can be selected to be stopped as well as a scene can be recalled by the OFF Button Dim UP DOWN Sent Broadcast or to individual groups Selectable on the layout configuration page Previous Next Page Displayed pages...

Page 7: ...s to a scene the function can be controlled from another device that recalls the corresponding scene 2 Group Control Dim UP DOWN Send UP or DOWN commands as long as the button is pressed Only available if the group is ON Group ON OFF Sends Recall MAX or OFF to switch group ON OFF Previous Next Page Displayed pages can be configured on the layout configuration page OFF Sent Broadcast or to individu...

Page 8: ... Page Deactivation of Touchscreen Group ON OFF Sends Recall MAX or OFF to switch group ON OFF It is also possible to dim the group by pressing and holding a group button This design symbolizes that the group is ON This design symbolizes that the group is OFF Deactivate the touch panel for 20 seconds to clean the screen ...

Page 9: ...erating range Selection of sequence schedule or schedule list Hold the button to open the pop up window to load other processes Dim UP DOWN Sent Broadcast or to individual groups Selectable on the layout configuration page operating range Short press ON OFF operating range Selection of operating range Each group with DT8 RGB control gears or Broadcast can be selected Color selection color informat...

Page 10: ...ange can be selected 4 Configuration and Settings Via the gear wheel button in the menu bar the setting page can be entered The menu Configuration and the button with the clock symbol refer to display and layout related settings whereas the other menus are either used for commissioning or for activating functions Please find a overview of the display related settings below Date Time Timezone Confi...

Page 11: ...o firmware version Name of Display Factory Defaults Action at Net Recovery e g autostart of schedule list DALI Numbering V106 and higher DALI Routing Routing of scene and group commands Names Names for Sequences Names for Scenes Names for Groups Names for Schedules Layout Activation Deactivation of preconfigured Sites Scene Control Group Control Status all groups DT8 Color Control Scheduler Master...

Page 12: ...e In the following chapters the most important display related settings are explained 4 1 Design Three different default backgrounds are available Design 1 Design 2 Design 3 User defined Background Furthermore a customized background image can be used The background image needs to be a 800 x 480 pixel PNG Portable Network Graphic file and has to be named background png The image can be copied to t...

Page 13: ... about 2 minutes Furthermore it is possible to add a pincode protection to the screen saver and or the configuration page Default Pin for Lock Configuration 1234 Default Pin for Lock Panel 5678 The Master Pin 1220 does always unlock the panel The screen saver image needs to be a 800 x 480 pixel PNG Portable Network Graphic file and has to be named screensaver png The image can be copied to the DAL...

Page 14: ...106 the menu bar can be activated deactivated by pressing 5 seconds on the left top of a controls site embedded and user defined If a PIN for settings is enabled the function is pin protected 4 5 Site Numbering Up form V106 the site numbering can be changed by the customer Therefore in Settings Layout show site numbering has to be enabled Then the site number of each site is shown between the arro...

Page 15: ...m extension search for already installed ballasts on the bus by scanning all available DALI addresses on both DALI buses additionally the addressing algorithm will be started for DALI ballasts that have no short address Re initialisation deletes all DALI addresses removes all DALI groups and starts a new addressing routine This will delete and readdress all ballasts on the bus Grouping only no sea...

Page 16: ...s can be added to or removed from the 16 DALI groups Grouping Note A control gear ballast can be assigned to several groups Selecting a ballast A ballast can be optically selected with the left right arrows The selected ballast will give an optical feedback switched to DALI MAX Level SAVE Group Save Group Settings to Display and Control Gear LOAD Group Load and Edit another group Active Group Indi...

Page 17: ...e device will be deleted not the device address itself Add Address An address can be added to a group either by drag drop action or by using the Add to Group button Note The group information will be stored into the ballasts on the DALI bus only after the Save icon has been pressed To change the actual group tap the load symbol Note Addresses on DALI A range from A0 63 or A1 A64 and Addresses on D...

Page 18: ...r further setting options are available such as color temperature or RGB color value DALI DT8 devices these special properties can be edited by tapping the corresponding field The color temperature can be entered via a keypad for editing the color of a scene you will be redirected to the Color Scene configuration menu Hint Only DT8 devices which identify themselves as color type Tc or RGBWAF are s...

Page 19: ...pad Color Selection for a RGBWAF Group of a Scene Select Color R G and B and press back detailed settings more allow the definition of exact values and the configuration of additional channels W A and F Colortemperature Numpad 0 20000K Select Color Range 1 Red Blue 2 Blue Green 3 Green Red Back Cancel Accept Details ...

Page 20: ...aded and sent to the ballasts for an optical feedback When using the save function a dialog box will pop up and ask for the scene number you want to use for saving copy function When saving a scene you can decide if the stored scene values should be used to effect the group status evaluation ON or OFF Select Scene Number you want to use for Saving the Settings Option Use Scene Values for Group Sta...

Page 21: ... entered directly by selecting Color Scenes in the basic settings menu Note Simple method for storing and recalling colors with the help of DALI Scenes The color scenes menu is group oriented in contrast to the scene menu which is scene oriented that means that the color is only set for the selected group After the effective range has been selected you can edit set and test all color values for th...

Page 22: ...ll be saved All other actions pressing any other key result in cancelation of the scene configuration and the original color setting is being restored If a scene has been saved for all devices broadcast ALL is displayed in footer during color selection and in addition undertaken further editing within a group the color might not match original settings Therefore these specific scenes are marked wi...

Page 23: ...m length of 20 sec and a maximum length of 24 hours There is only one active sequence parallel running sequences are not possible The active sequence can again be changed using load sequence and stored using save sequence active Sequence sequence and assigned name Scene move scene to timeline with drag drop Settings configuration of sequence length and repitition Navigation control buttons to navi...

Page 24: ... and additionally pressing the button delete element By holding the scene rhombus on the timeline a pop up will open for more precise configuration Here S1 from previous example Day Schedules also referred to as Schedules SDL can be configured like sequences One difference Day Schedules are limited to 24 hours and their timing is related to the actual time of the day Sequences can be embedded in s...

Page 25: ...will stop In the week plan also referred to as Schedule List SDLL schedules can be assigned to each day For each day one Schedule from a list of seven options can be chosen Stopping endless sequence with daytime related sequence The sequence recall of SQ1 stops SQ2 which was defined as an endless sequence Also long time sequences can be stopped in this manner Activate SDLL ...

Page 26: ...de Tc and luminaries have to support various shades of white light In this setting mode each minute the color temperature of the according daytime is being broadcasted All DT8 control gears mode Tc that respond to these commands will adjust their shade of white Note Whenever this mode is activated newly started scene commands regarding DT8 luminaries will be overruled after a minute when new comma...

Page 27: ...el For firmware V103 the IP of the display has to be added to the secure site list Control Panel Java Security Sitelist Add IP Adress to list e g http 192 168 0 164 Alternatively you may use a VNC viewer to remote control the DALI display 1 Java applet using VNC protocol firmware version V103 is compatible with Java8 V102 is compatible with Java7 Oracle does often change the security settings and ...

Page 28: ...ielle Elektronik GmbH With newer java versions you also have to agree to run the application furthermore it may be necessary to empty the browser cache Once you have access you can remote control the display and navigate freely through all the menus ...

Page 29: ...you can open another page Currently you will find a download and upload tool there With the help of this tool you can upload customized pics as well as save and restore configuration files and finally update the firmware Group Control The display pages are shown in the browser and can be controlled via browser Extended Menu Click more ...

Page 30: ...evious downloaded configuration screensaver png customized screensaver 800 480 background png customized background 800 480 Furthermore user defined images and configuration files for customized pages can be uploaded Contact the manufacturer for further details As alternative to the browser you can use a VNC Viewer to remote access the DALI Display Note the download upload site can be accessed onl...

Page 31: ...he version number of the update There are two possibilities to update the Display USB Stick Unzip the file DALIDisplay_Vxxx zip into the root directory of an USB stick Then plug in the USB stick into the DALI Display and follow the instructions on the screen Ethernet Just upload the file DALIDisplay_Vxxx zip on the upload page of the DALI Display web page details see chapter 6 ...

Page 32: ...edback on the luminaire s status on or off is especially convenient if the Display is placed in a different location 8 2 Room overview of a floor with controllable luminaries The Display shows the main floor of a building The light can be turned on off by pressing the images of luminaries in the various rooms Alternatively the luminaries can be controlled with scenario buttons located next to the ...

Page 33: ... off rooms visualization of lighting status and direct control of luminaries conference room short click Light on off hold button enter detailed room overview back return to main floor plan scenes scenes regarding the conference room Aus OFF light off in conference room dimming light brighter darker luminaries optional direct control of luminaries ...

Page 34: ...cene Using a DALI scene for storing color information only without brightness level level MASK DALI Digital Addressable Lighting Interface standard for lighting control IEC 62386 Device Type 8 DALI standard for colour control short DT8 all device requirements regarding colour control via DALI are combined in the norm IEC 62386 209 individual device address Each DALI device is equipped with an indi...

Page 35: ...dustrielle Elektronik GmbH stopped any time Schedule List SDLL Week schedule with a 7 day plan For each day a time related schedule can be set Sequence SQ Time related process can be started paused and stopped any time Scene S Lighting scenario ...

Reviews: