www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
8
Warranty
LUMISHORE Ltd warrants the SY300 SUPRA lighting system to be free from defects in workmanship for
a period of three years, starting from the date of original purchase. Should your lighting system have a
problem during this period, please contact your dealer as soon as you become aware of the defect.
Misuse, abuse, improper installation, neglect, improper shipping, damage caused by disasters (e.g. fire,
flood and lightning), installation by unqualified personnel, unauthorized repair or modification will
void this warranty. For the avoidance of confusion and doubt, non compliance with all installation,
maintenance and operating instructions in this document constitute non conformance with warranty
terms.
Full warranty details are available at www.lumishore.com.
Troubleshooting
In the event of one or more of the lights not lighting up then check the LED status on the driver (at the
back of the light). The LED will either be continually ON (healthy), OFF (no power to driver) or flashing.
Please refer to the table below for what the number of flashes means and what action to take.
In the event of an issue, record the serial number(s) of the light(s) and contact your local dealer.
If a light does not switch on or function properly, it should be disconnected from the power source.
LED Status
No LED light on driver
Solid LED
Flashing 2 times
Flashing 3 times
Flashing 4 times
Flashing 7 times
Flashing 8 times
Continuous rapid flashing
Light temp too high
Driver temp too high
LED array voltage out of range
Light not detected
Driver program corrupt
Could happen when light is out of water or next
to exhaust
Driver is mounted too close to an engine or exhaust
Check the connections between light and driver
Check light in each colour to determine if all colours
are working
Light is not connected or cable is cut or pinched
Light has been connected incorrectly to the driver
Reset driver by switching off power for 1 minute, and
then switching on again
Contact LUMISHORE if problem persists
Meaning
No power to driver
Power On
Low input voltage to driver
Action to take / Things to check
Check fuse / breaker
Check connections
Check voltage at input to driver connections
Driver is receiving voltage and operating properly
Check the switch is operating correctly
Check power connections or battery voltage
Warranty & Troubleshooting