Light Operation (Momentary switch):
1. Press switch once to turn ON.
2. Press and hold to dim lights.
3. Press switch once to turn OFF.
Note : Black wire from each light and LUX Module should connect to common ground
Max 16 lights per LUX Light Module
10-31v
GND
Cut & Isolate
RED & BLK
LUX Light
Module
Switch (Momentary)
MFD Control
(Optional)
Lumi-Link
Command Center
1
6
2
5
3
4
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
Wiring Diagrams:
Wiring should be carried out as per ABYC guidelines. The Lumishore Spotlight - Curved will operate with a simple On/Off
switch, it can also be controlled by MFD via LUX Light Control Module and Lumi-Link Command Center. For further electrical
installation instructions and wiring diagrams please refer to the LUX Light Module installation guide (45-0145). Each lighting
circuit must be fused accordingly.
Voltage
10-31VDC
Model of Light
20”
30”
40”
50”
Amps (max) @ 12V
12.8A
19.3A
25.7A
32.1A
Amps (max) @ 24V
6.2A
9.7A
12.9A
16.0A
Light Operation (Latching switch):
- Turn switch ON to power light at full power.
Single switch wiring - Control via latching switch
Switch (Latching)
Fuse
YEL - DATA
RED - 10-31V
BLK - GND
DO NOT connect red and black power wires of light to the LUX Module.
Feed each light with it’s own fused supply.