1 4 |
P a g e
BLACKCOMB
4.1
Controllers
LB4
Series
LBH4
Series
Simplistic in operation, these systems feature a tri-colour
LED that indicating system status and a 4-digit display to in-
dicate lamp life remaining. Pressing the button will change
the display to indicate total running time. When the UV lamp
is on and within its operating age, the LED will be green.
When the UV lamp is not on or the lamp life has expired,
the LED will be illuminated red and an audible buzzer will be
sounding. To remedy this condition, the UV lamp must be
replaced with a new genuine LUMINOR UV lamp.
BLACKCOMB
5.1
& BLACKCOMB
6.1
Controllers
LB5 / LB6
Series
LBH5 / LBH6
Series
A full colour LCD screen provides the user with a detailed
description of the system’s performance in addition to pro-
viding any applicable fault messages and system diagnostics.
The controllers used in both the BLACKCOMB
5.1
and BLACK-
COMB
6.1
are identical. The difference is that the BLACK-
COMB
6.1
series of products includes a UV intensity monitor.
All BLACKCOMB
5.1
and BLACKCOMB
6.1
controllers include an
“infinite expandability port” located on the right side of the
controller. Simply plug in an optional UV sensor module into
the expandability port of a BLACKCOMB
5.1
controller and the
system will now monitor the UV intensity of the system!
BLACKCOMB
5.1
& BLACKCOMB
6.1
Power-up Sequence
On start up, the controller will run through a diagnostic start-up and the sequence will be dis-
played as follows on the colour LCD:
Next, the controller checks for and initializes any optional modules that may be attached to the
system.
Optional Modules Check
- UV Sensor
- Solenoid
- 4-20 mA
- WIFI
- Remote Alarm
- Flow Meter
OR