5. RESET

In the case you need to reset the unit without the web interface, the 

GigaCore 10 and GigaCore 10 with PoE off ers diff erent levels of reset, 

based on the ones you can fi nd in the web interface.

 

Reset: 

The unit is brought back to its default confi guration, 

with the default IP address printed at the back of the unit.

 Profi les stored in the device are preserved

 

Default login: admin

 

Default password: No password

 

Reload Default:

 The profi le stored in slot one is reloaded. The 

“Reload Default” is available only if the profi le stored in slot 

one has been locked through the utility menu. If this profi le 

is set with a password, then the user will need to enter it 

through the web interface to access the switch’s menu.

 

Default login: admin

 

Default password: No password

 

Factory Reset:

 With a factory reset the device is fully reset to 

the state it left Luminex and ALL data will be erased.

 

Default login: admin

 

Default password: No password

THE FOLLOWING RESET PROCEDURES CAN ALSO BE ACHIEVED 

WITH THE FRONT-END PANEL’S JOG!

5.1 Reset

Condition 1: The device is currently running

Condition 2: There is no profi le set as default profi le

Hold the mode button for at least fi ve seconds to see the four status 

LEDs blink red. Releasing the mode button while the LEDs are blinking 

red will reset the unit.

Be aware that releasing the mode button during the fi rst fi ve seconds 

before the LEDs start blinking red will cancel the operation.

Be aware that releasing the mode button during the fi ve seconds after 

the LEDs are blinking red will cancel the operation.

5.2 Reload Default

Condition 1: The device is currently running

Condition 2: The profi le stored in slot one needs to be locked through 

the utility menu

Hold the mode button for at least fi ve seconds to see the four status 

LEDs start blinking green. If you release the button whilst the LEDs are 

blinking green, the unit will reload the profi le stored in slot one.

If you wait an additional fi ve seconds, the status LEDs will start blinking 

red to provide you with a reset.

Releasing the mode button while the LEDs are blinking red will reset 

the unit.

Be aware that releasing the mode button during the fi rst fi ve seconds 

before the status LEDs are blinking green will cancel the operation.

Be aware that releasing the mode button during the fi ve seconds after 

the status LEDs were blinking red will cancel the operation.

5s

Hold the reset button

Release the button = 

Reload default

Release the button = Reset

Function

5s

5s

GREEN BLINK

RED BLINK

Timing

5s

Hold the reset button

Release the button = Reset

Release the button = Cancel

Function

5s

5s

RED BLINK

Timing

24

Summary of Contents for GigaCore 10

Page 1: ...USER MANUAL GIGACORE PRODUCT FAMILY GigaCore 12 THANKS FOR CHOOSING LUMINEX Description User Manual GigaCore 12 REVISION 20220623 REV 2 8 7...

Page 2: ...PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONEL AVERTISSEMENT AUCUNE PI CE CONTENUE L INT RIEUR NE PEUT ETRE R PAR E PAR L UTILISATEUR VEUILLEZ CONFIER TOUTE R PARATION UN PERSONNEL QUALIF...

Page 3: ...ronic equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If...

Page 4: ...3 GIGACORE FEATURES EXPLAINED 9 3 1 RlinkX 9 3 2 Groups VLANs 10 3 3 MultiLinkX 10 4 CONFIGURATION 12 4 1 Connecting to the web interface 12 4 2 Status Page 12 4 3 Global Page 14 4 4 RlinkX 17 4 5 Gr...

Page 5: ...n all your lighting audio and video protocols to di erent co lour groups and send them over the same network Luminex takes care of the rest and makes sure every device receives the right signal ArtNet...

Page 6: ...gain After connecting the power cable correctly the power LED indicator on the front panel will light up green The GigaCore 12 and GigaCore 12 with PoE requires standard AC power distribution from 100...

Page 7: ...port RlinkX Shows the status of RlinkX for each port Port Link Speed Shows the status of RlinkX for each port C ETHERCON PORTS 10x EtherCon 10 100 1000Mbs port D REAR PORT STATUS LEDS RlinkX Shows th...

Page 8: ...to default The user pro les will be preserved though For more detailed information on how to reset the device and what reset options are available please check chapter 5 of this manual 2 4 LED indica...

Page 9: ...ween20and40ms By default all GigaCore ports have RLinkX enabled which means you can interconnect any GigaCore switch between each other All redun dant paths will be created automatically by the switch...

Page 10: ...t of the time a redundant link set with RLinkX between two Gi gaCore switches will be good for the everyday event A 1000Mbps link is more than enough for most of the current applications However it ca...

Page 11: ...the following parameters Source Mac Address Source IP Address Source Port TCP UDP Destination IP Address Destination Port TCP UDP The ports included in the aggregation Rx 400Mbps Rx 400Mbps Rx 400Mbp...

Page 12: ...55 255 0 0 Connect your computer to the switch with a network cable and launch your favourite web browser Type the IP address of the switch in the address eld and press enter You ll be prompted to ent...

Page 13: ...Dynamic Host Con guration Protocol 4 3 Global Page The global page consists of four sub menus If your network is equipped with a DHCP server you can enable the DHCP client of the switch for it to rece...

Page 14: ...ault security parameters A Reset This menu allows the user to bring the switch into di erent levels of reset 1 Preserve IP Settings Tick the upper checkbox if you wish to bring the device back to the...

Page 15: ...recover from this o set is to restart the switch and thus reset the ber PHYs to eliminate the o set This is needed to have a synchronized system Via the utilities web page of the GigaCore theusercanno...

Page 16: ...to reload the previous rmware The downgrade process takes about 1 minute C Security The user can use this feature to set a password to protect the access to the web interface The default login for th...

Page 17: ...y is active and operational 4 4 1 Advanced MultiLinkX ouraggregationprotocol hasbeendesignedtowork aw lessly with RLinkX our redundancy protocol To provide users with a more advanced and e cient metho...

Page 18: ...u need to have at least one port on one of the switches set in this group in order to be able to reach the web interface of any of the switches Group 2 to 20 These are the generic groups to be used fo...

Page 19: ...ocking protocol by timestamping packets at the hardware level With PTPv2 the GigaCore can be part of the clock domain which is necessary for protocols such as AES67 The user can enable disable PTPv2 c...

Page 20: ...erCon ports on the front with a maximum of 30W per port PoE compliant 4 5 2 MultiLinkX MultiLinkX alsoknownaslinkaggregation allowsyoutogathersever al links together in order to increase the available...

Page 21: ...ish to modify B Enable or disable these port s C Select the priority for the port s D Apply your new parameters The priority of a port is used when the switch reaches the limit of its maximum output p...

Page 22: ...e switch the user can select a pro le to export to a computer Then fromthesamecomputer theuserwillbeabletoloadthispro le into an empty slot on another switch Exchanging pro les between switches can be...

Page 23: ...O THE WEB INTERFACE OF THE SWITCH YOU RE WORKING WITH ALSO PAY ATTENTION THAT THE IP ADDRESS THAT WILL BE RE LOADED WITH THE PROFILE DOESN T CONFLICT WITH AN OTHER IP INTHE NETWORK THE SWITCH SWEB INT...

Page 24: ...Ds blink red Releasing the mode button while the LEDs are blinking red will reset the unit Be aware that releasing the mode button during the rst ve seconds before the LEDs start blinking red will can...

Page 25: ...rthestatusLEDsstopped blinking red will cancel the operation Sometimes it is required to get more help with your device or applica tion There is a knowledge base available online that gets updated on...

Page 26: ...notice Luminex its employees or appointed representatives will not be held responsible for any damages to software hardware or data howsoever arising as a direct or indirect result of the product s me...

Page 27: ...EFFECTIVE RELIABLE ACCESSIBLE YOUR NETWORK SOLUTION FOR AUDIO VIDEO AND LIGHTING 27...

Page 28: ...Slamstraat 13 3600 Genk Belgium T 32 11 812 189 info luminex be www luminex world...

Reviews: