 ENG

SN

Serial number 

Keep dry

For indoor use only 

Double-insulated

(Class II electrical)

DC (direct current)

power supply

Do not place in household 

waste. Dispose of at a 

recycling centre.

Read instructions for use

Caution

Member of the ‘Green Dot’

recycling scheme

Recyclable

Manufacturer:

Outside In (Cambridge) Ltd,

3 The Links, Bar Hill,

Cambridge, CB23 8UD, UK.

European Declaration

of Conformity:

Class I Medical Device

Safety

Safety

If the unit is damaged contact Lumie before use.

Keep away from water and damp. 

For indoor use only. 

The unit gets warm when the light is on, so make sure that it is not covered.

Use only the mains power adaptor supplied.

Keep the power supply and cable away from heated surfaces. If either are damaged they 
should be replaced with an approved Lumie product. 

To power down or reset the unit, remove the mains power adaptor from the wall socket.

Do not attempt to service or modify any part of the unit.

If the unit has been stored outside the recommended temperature range (5 °C to 35 °C), 
allow it to stand for at least 1 hour before applying power to avoid condensation or 
overheating.

Not to be used by or on individuals who are unconscious, anaesthetised or incapacitated 
e.g. under the influence of alcohol.

Electromagnetic compatibility

This product conforms to the electromagnetic compatibility (EMC) standard for medical 
devices and is unlikely to cause interference affecting other electrical and electronic 
products in its vicinity. However, radio transmitting equipment, mobile phones and other 
electrical/electronic equipment can interfere with this product; if this happens simply move 
the product away from the source of interference. In rare cases where product function is 
lost due to EMC effects, disconnect the product from power source for 5 seconds and then 
restart. If the problem persists, please contact Lumie.

For further detailed information on the electromagnetic environment in which the device can 
be operated refer to the website: www.lumie.com/pages/e-m-c.

Disposal

At the end of its life, do not throw the unit out with normal domestic waste. Please take 

 

it to an official recycling point to be disposed of responsibly.

Summary of Contents for bodyclock glow 150

Page 1: ...bodyclock spark 100 glow 150 ENG FRA DEU ESP...

Page 2: ...mperature range 5 C to 35 C allow it to stand for at least 1 hour before applying power to avoid condensation or overheating Not to be used by or on individuals who are unconscious anaesthetised or in...

Page 3: ...al Affective Disorder and winter blues cope with dark winter mornings 2 At bedtime a fading sunset helps you naturally unwind by promoting the production of the sleep hormone melatonin 3 Lumie invente...

Page 4: ...ogram The hours will flash Use or to set the hours Press to confirm and continue The minutes will flash Use or to set the minutes Press to confirm and exit to the current time Lumie Bodyclock is prese...

Page 5: ...light intensity Use or to set the final brightness of the sunrise 0 for no sunrise or a level from 1 to 5 Press to confirm and continue M Alarm beep Use or to set the volume of the optional alarm beep...

Page 6: ...d continue O Wake sound Use or to set a wake sound for the end of the sunrise 0 No alarm sound 1 Beep 2 Tropical birds 3 Blackbird 4 Cafe 5 Goats 6 Steam train 7 Thunderstorm 8 Waves 9 Crickets 10 Whi...

Page 7: ...ion of the sunset 20 30 or 45 minutes Press to confirm and continue N Nightlight Use or to set a nightlight 0 for no nightlight sunset fades to off or a level from 1 to 5 sunset fades to nightlight Pr...

Page 8: ...to sleep You can change this setting if you prefer the display to stay on at LOW brightness when the room is dark Use the switch in the base of the unit to set OFF or LOW LOW OFF Display brightness To...

Page 9: ...m The hours will flash Use or to set the hours Press to confirm and continue The minutes will flash Use or to set the minutes Press to confirm and exit to the current time Bedside light Lumie Bodycloc...

Page 10: ...nfirm the alarm is activated for example Activate the alarm You ll wake with a gradual sunrise and any other sunrise options you have set See also Alarm time and sunrise options page 5 To deactivate t...

Page 11: ...s Using the fading sunset When you re ready to sleep a fading sunset can help you to relax and unwind See also Sunset options page 7 To activate the sunset Use or to set the light level Press S The di...

Page 12: ...e for individual LEDs to fail This will make only a negligible difference to light output and you can continue to use the product Warranty This unit is covered under warranty against any manufacturing...

Page 13: ...15 W Operating temperature range 5 C to 35 C Storage transport temperature range 25 C to 70 C Class I Medical Device Contact us If you have any suggestions that you feel could help us improve our pro...

Page 14: ...Lumie is a registered trademark of Outside In Cambridge Ltd 3 The Links Trafalgar Way Bar Hill Cambridge CB23 8UD UK Lumie 2019 BC100 150i1904 Distributor details...