Lumex FR601P Series Assembly And Operating Instructions Manual Download Page 8

LX_FR601-INS-LAB-RevD21 8

Upright Position

First Recline Position

(TV Position)

Second Recline Position

(Full Recline Position)

Trendelenburg Position

(Shock Position)

Trendelenburg

activation pedal

SIDE TABLE OPERATION

See illustration at right for side table 
operation.

Raise Side Table

Raise the side table all the way up 
and slide in toward the armrest until 
tabs engage slots in mount bracket. 
Press down lightly on table to ensure 
locking tabs are engaged.

Lower Side Table

Lift the side table up slightly until 
tabs disengage slots and pull table 
away from armrest. Lower side table 
to self-storing position.

RECLINER OPERATION

The Lumex Series FR601 Recliner features three positions for patient comfort. The fourth position 
is a Trendelenburg (or Shock) Position that must be activated by a caregiver. The Trendelenburg 
Position CANNOT be activated by a patient while in the recliner.

First Position (Upright Position)

The first position is the 

Upright Position

. This position is ideal for 

patient transport and can be used to initiate patient treatment / 
therapy.

Second Position (First Recline Position)

The second position is the 

First Recline Position

 and is also known as 

the “TV” position. This position is ideal for patient treatment, rest and 
reading.

To Achieve Second Position / First Recline Position:

•  Reclining by patient: Place hands on armrests and push body 

against recliner back to recline yourself to desired position. To 
bring yourself up, place hands on armrests and pull yourself up 
while leaning your body forward, away from the recliner back, 
while at the same time pushing down evenly on the footrest with 
your legs.

•  Reclining by caregiver: Standing on either side of the recliner, 

grasp the armrest with one hand and the push handle with the 
other hand. Push back on push handle to recline. To return, grasp 
push handle and pull forward to raise the recliner’s back.

s

  NOTICE: DO NOT use the footrest by itself to return the recliner to an upright position from 

any recline position. Doing so may damage the recliner mechanism. Follow the instructions 

above to operate the recliner.

side table

(stored position) 

side table

(engaged position)

tabs engage into

slots on side table

mount bracket

side table

mount bracket

3

/

8

" clevis pin

attachment

armrest

side table

(disengaged position) 

Side Table

Summary of Contents for FR601P Series

Page 1: ...Series FR601PL Clinical Care Recliner with Pivot Arm Upholstered Arms and Extended Legrest Series FR601PHL Clinical Care Recliner with Pivot Arm Upholstered Arms Heat and Massage and Extended Legrest...

Page 2: ...ENDELENBURG POSITION ALSO KNOWN AS SHOCK POSITION 9 PIVOT ARM OPERATION 10 OPEN THE PIVOT ARM 10 CLOSE THE PIVOT ARM 10 FOOTPLATE OPERATION 11 RECLINERS WITH HEAT AND MASSAGE OR HEAT ONLY FEATURE 12 I...

Page 3: ...s in other chapters or sections which may be the same as or similar to the following or specific to the operations Please note the following special statements used throughout this manual and their si...

Page 4: ...rdous condition which may result in serious injury and will void the warranty WARNING This product can expose you to chemicals including Di 2 ethylhexyl phthalate DEHP which is known to the State of C...

Page 5: ...RODUCT DESCRIPTION upholstered back pivot arms upholstered seat upholstered legrest skirt upholstered footrest self storing side table frame frame Trendelenburg activation pedal pivot arm release push...

Page 6: ...echanism 2 Remove two pre installed threaded knobs from back one on each side 3 Carefully guide the upholstered back onto the mechanism inserting both bayonet links at the same time through the two cu...

Page 7: ...ks in a straight line with the recliner frame To release the directional lock press on the raised portion of the actuator tab until the lever is back in the normal operating position Models FR601PL FR...

Page 8: ...t Recline Position The second position is the First Recline Position and is also known as the TV position This position is ideal for patient treatment rest and reading To Achieve Second Position First...

Page 9: ...iner grasp the armrest with one hand and push handle with the other hand Push back on push handle to recline To return grasp push handle and pull forward to raise the recliner back Trendelenburg Posit...

Page 10: ...er 1 Pivot the Arm back toward the front of the recliner until the pivot arm stops Step down on the YELLOW RELEASE LEVER located toward the front of the recliner Continue to push the pivot arm over th...

Page 11: ...can now rest their feet on the footplate while being transported To return the footplate to the stored position push the footplate back underneath the recliner until it stops and is safely stored und...

Page 12: ...njury caused by improper assembly or use of this product Description The Heat and Massage Unit offers three levels of seat and back heat as well as a gentle or firm massage function for just the lower...

Page 13: ...ly Installation Instructions 1 Place the back cushion over the vertical bayonet lugs of the recliner mechanism Secure the back on each side with the threaded screw knobs per the previous Upholstered B...

Page 14: ...tabs snap into place as shown above Connector Security Lock 5 If you need to replace the Hand Pendant remove the small white connector security lock as shown above 6 Remove the tape holding the back...

Page 15: ...200RevA20 SEE OPERATING MANUAL FOR COMPLETE INSTRUCTIONS HIGH HEAT PRESS 1 TIME MEDIUM HEAT PRESS 2 TIMES LOW HEAT PRESS 3 TIMES 3 The Heat and Massage Pendant Selector Switch Faceplate shown at above...

Page 16: ...The Heat Function Settings are as follows a Press selector switch for Setting 1 High Heat 104 F 40 C brightest LED b Press selector switch AGAIN for Setting 2 Medium Heat 101 F 38 6 C bright LED c Pre...

Page 17: ...s f Are all cable connections to the control module in place Are the connectors fully engaged g Are any of the connectors damaged h Are the wires within the connectors attached to the pins Each wire m...

Page 18: ...1 part isopropyl alcohol to 1 part water Info Using alcohol on a regular basis can affect the properties of the product Once a month you can use a soft bristle brush for a deeper cleaning Info Light...

Page 19: ...ing and maintaining noncritical medical equipment In the absence of a manufacturer s cleaning instructions follow certain procedures Clean noncritical medical equipment surfaces with a detergent disin...

Page 20: ...nurseries and neonatal units avoid unnecessary exposure of neonates to disinfectant residues on these surfaces by using EPA registered germicides in accordance with manufacturers instructions and safe...

Page 21: ...stic parts Product Metal Scrap Cable Scrap Electronic Scrap Plastic Recycling or Combustion FR601P X X N A X FR601PH X X X X FR601PHO X X X X FR601U X X N A X FR601UH X X X X FR601UHO X X X X FR601PL...

Page 22: ...re including but not limited to filters fuses gaskets lubricants and charts 4 Accessories or parts not provided by GF 5 Charges by anyone for adjustments repairs replacement parts installation or othe...

Page 23: ...autions 3 Info statement significance 3 Intended use 3 Introduction 3 K Key to symbols 21 L Limited warranty 22 N NOTICE statement significance 3 O Operation 7 P Pivot arm close 10 Pivot arm open 10 P...

Page 24: ...2019 GF Health Products Inc All Rights Reserved Graham Field and Lumex are trademarks of GF Health Products Inc Tente is a trademark of TENTE GmbH Co FED REP GERMANY GF Health Products Inc is an ISO...

Reviews: