1. Introduction

This manual should be used for initial set up of the system and for reference purposes.

1.1 General Information

LumexAir systems use most advanced technologies and mattress materials to deliver the

best quality, comfort and whisper-quiet operations to you and your customers. Most systems

in LumexAir are recommended for prevention and treatment of pressure ulcers up to and

including stage IV pressure ulcers.
This LumexAir range of system has been independently tested and successfully approved to

the following standards:

EN60601-1 / UL 60601-1

EN 60601-1-2

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-6

IEC 61000-4-8

IEC 61000-4-11

EN55011 CLASS B

EN 61000-3-2

EN 61000-3-3

FOR US AND CANADA ONLY

1.2 Intended Use

The system is a true low air loss replacement system suitable for high-risk patients. It is non-

alternating mattress designed with very low average pressure dispersion. The pulsation

function on the compact pump unit provides patients the message action to stimulate the

blood circulation and reduce the edema.

NOTE : Equipment not suitable for use in the presence of a flammable anesthetic

mixture with air or with oxygen or nitrous oxide.

E228589

53DG

Medical Equipment-Air Pump
with respect to electrical shock, fire and mechanical

hazards only in accordance with UL60601-1 and

CAN/CSA C22.2 No. 601.1

Summary of Contents for 763400A

Page 1: ...pe er ra at to or rs s M Ma an nu ua al l GF0500067REVA05 LowAirLossTherapy MattressReplacementSystem Model 763400A P Pl le ea as se e r re ea ad d t th he e m ma an nu ua al l b be ef fo or re e u us...

Page 2: ...Contents Important Safeguards 2 Introduction 3 Product Description 4 Installation 5 Operation 7 Cleaning 10 Storage 11 Maintenance 11 Troubleshooting 12 Technical Description 13...

Page 3: ...ice center for examination and repair 5 Keep the cord away from heated surfaces 6 Never block the air openings of this product or place it on a soft surface such as a bed or couch where their openings...

Page 4: ...61000 4 2 IEC 61000 4 3 IEC 61000 4 4 IEC 61000 4 5 IEC 61000 4 6 IEC 61000 4 8 IEC 61000 4 11 EN55011 CLASS B EN 61000 3 2 EN 61000 3 3 FOR US AND CANADA ONLY 1 2 Intended Use The system is a true l...

Page 5: ...It also provides excellent ventilation and keeps patients dry from humidity The 10 inch high mattress which consists of 8 inch high air bladders at the top and a layer of 2 foam at the bottom provide...

Page 6: ...bed frame Please note for the foot end Mattress can be secured firmly by fixing the elastic straps at the bottom bed frame NOTE Please cover the mattress with a cotton sheet to avoid direct skin cont...

Page 7: ...er Do not use it for any other purpose 5 Then turn the main power switch ON The power switch is located on the right side panel of the pump unit NOTE Ensure the CPR connectors are sealed completely In...

Page 8: ...r outage during normal use ALARM MUTE Enable and disable the audible alarm feature Press this button to silence the audible alarm The alarm buzzer will sound again after 3 minutes if the pressure has...

Page 9: ...tomatically STATIC For true low air loss therapy mode similar to a regular air mattress with very low air pressure support and true low air loss therapy PULSATION For pulsating and true low air loss t...

Page 10: ...re Indicator is off it indicates the mattress has reached to its preset softness Patient can lie on the mattress NOTE Check to see if the suitable comfort range or pressure setting is selected by slid...

Page 11: ...button on the control panel When power failure situation occurs alarm will last until backup battery is low or it can be turned off by manual operation Once power failure alarm situation is resolved i...

Page 12: ...oblems or malfunctions to local distributors 7 2 Air Filter Replacement The air filter should be checked and dusted periodically once per month 1 Two foam type filters are used One is located on the b...

Page 13: ...oo long Release some air by disconnecting the air tube connector and change to preferred setting Air Mattress is loose Check if all the snap buttons or straps of mattress are all securely fastened Che...

Page 14: ...orage 10 to 90 non condensing Shipping 10 to 90 non densing Atmosphere 700 hPa to 1060 hPa Classification Class II Type BF IPX0 Applied part Air Mattress Not suitable for use in the presence of a flam...

Page 15: ...U S A Corporate Headquarters Graham Field Health Products 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 http www grahamfield com...

Reviews: