background image

 

 

     

English 

17

 

Chapter 6 Introductions to Control Panel 
Buttons 

 

 

Icon 

Function Descriptions

 

 

Turn on and off 

 Short press: power on (under stand by) 

 Press for 1 second: turn off (under power on) 

 Press for 10 seconds: force to turn off 

 

Battery level check 

 

Auto Tune 

Automatically adjust the image to have the best brightness 
and focusing performance 

,

,

,

 

Left, right, up, down buttons, used for moving in a direction 
at the partial enlarged mode 

 

Enable/Disable the partial enlarged mode 

  / 

 

Adjust the brightness of the image 

  / 

 

Zoom in/out images 

 

Rotate image: 0°/ 90°/ 180°/ 270° /Vertical flip/Horizontal flip 

 

LED lamp mode toggle switch: off / brightness 1 / brightness 
2 / brightness 3 

<Remark>

Brightness 3 is the brightest state 

 

Freeze 

Freeze the current image to remain temporarily on the 
screen. Press again to defreeze 

Summary of Contents for DC-W80

Page 1: ...W80 4K Document Camera User Manual English Important To download the latest versions of the Quick Start Guide multilingual user manual software driver etc please visit Lumens https www MyLumens com support ...

Page 2: ...e 10 4 2 Installation and setup 10 4 3 Connecting to a computer and use Lumens software Wi Fi mode 11 4 4 Connect to a projector monitor or HDTV HDMI mode 11 4 5 Connecting to a computer and use Lumens software USB Mode 12 4 6 Installing Application Software 12 Chapter 5 Start Using 13 5 1 Direct Use HDMI Mode 13 5 2 Use with Ladibug Wi Fi Mode 14 5 3 Use with Ladibug USB Mode 16 Chapter 6 Introdu...

Page 3: ...part of the image 19 Chapter 8 Wi Fi Connection Setting 20 8 1 Network connection 20 8 2 Log in to the web page 20 8 3 Web Page Menu Function Description 21 Chapter 9 Set DC W80 as an AP 30 9 1 Connection Diagram 30 9 2 Device Requirements 30 9 3 Setting DC W80 30 Chapter 10 DIP Switch Setting 33 10 1 Description of DIP 33 10 2 Resolution Switch 33 Chapter 11 Troubleshooting 34 Supplier s Declarat...

Page 4: ... product Lumens Digital Optics Inc hereby reserves the right to make changes to product specifications without prior notice The information in this file is subject to change without prior notice To fully explain or describe how this product should be used this manual may refer to names of other products or companies without any intention of infringement Disclaimer of warranties Lumens Digital Opti...

Page 5: ...lcohol or volatile solvents for cleaning 5 Batteries for products or accessories with batteries 5 1 When replacing batteries please only use similar or the same type of batteries 5 2 When disposing of batteries or products please adhere to the relevant instructions in your country or region for disposing of batteries or products Precautions This symbol indicates that this equipment may contain dan...

Page 6: ...English 5 Chapter 2 Package Contents DC W80 USB cable USB 2 0 Quick Installation Guide ...

Page 7: ...hapter 3 Product Overview 3 1 Overview 3 2 Extension angle Caution Please only operate in the extended angles as illustrated Improper usage may damage the machine Support Arm Control panel LED Indicator Lens Lamp ...

Page 8: ...hine failure 3 4 I O functions Introduction NO Item Function Descriptions 1 Power LED Indicator Display the status of the machine Please refer to 3 5 Description of LED indicator 2 Wi Fi LED Indicator Display the status of the Wi Fi Please refer to 3 5 Description of LED indicator 3 Battery LED Indicator Display the status of the battery Please refer to 3 5 Description of LED indicator Back View F...

Page 9: ...ower 3 5 Description of LED indicator Name Indicator Status Power Flickering blue light Startup in progress initialization Blue light stays lit Startup completed Flickering red light A startup failure or error has occurred Pink light stays lit Already powered on indicating low power and need to connect to the USB cable for charging Wi Fi Blue light stays lit Switched to the Wi Fi Mode and the star...

Page 10: ...English 9 3 6 Relative position of the presenter and document Computer Projector ...

Page 11: ...ht Extended 306 x 140 x 373 mm Closed 137 x 140 x 270 mm Weight 1 35 kg 4 2 Installation and setup Please set up the DIP switch setting first Refer to Chapter 10 DIP Switch Setting Please confirm that the product is switched to the desired mode Wi Fi HDMI USB Wi Fi Mode HDMI Mode USB Mode ...

Page 12: ...i Fi mode Please download the relevant software from Lumens website For more information on the connection method please refer to Chapter 8 Wi Fi Connection Setting 4 4 Connect to a projector monitor or HDTV HDMI mode Computer HDMI cable Monitor Projector HDTV or or ...

Page 13: ...trol DC W80 Capture and record images Annotate the image highlight important details and save it Support the full screen function Caution Please download the relevant software from the Lumens website For installation steps and software operation please refer to the Ladibug 4K software user manual 4 6 1 System Requirements Windows System Windows 7 or later Chrome system Mac System Mac OS X 10 12 an...

Page 14: ...all the power bars are full and the green light is constant on 2 Place an object to be displayed under the camera 3 Turn on the power and adjust the operation mode according to the connection method 4 Adjust the support arm and lens to the appropriate positions 5 Press AUTO TUNE button to optimize the image 6 You are ready to teach present Computer Projector ...

Page 15: ...lue Open the Wi Fi network list on the computer and choose DC W80_5G_XXXXXX XXXXXX last six digits of the MAC address Enter the connection password default password 88889999 to enable the connection 5 2 2 Use Ladibug to connect to DC W80 1 Open Ladibug click to open the Search Window and select Wireless Document Camera 1 2 ...

Page 16: ...Click and select a DC W80 in the list after the search is completed 3 Log in as an Admin or a Viewer The default password for Admin is 9999 4 After connecting to DC W80 by clicking Log In you can start using it 1 2 ...

Page 17: ...3 Use with Ladibug USB Mode 1 Switch to USB mode and use a USB cable to connect DC W80 and the computer 2 Open Ladibug click to open the Search Window and select USB Document Camera 3 You can start using DC W80 1 2 ...

Page 18: ...e the best brightness and focusing performance Left right up down buttons used for moving in a direction at the partial enlarged mode Enable Disable the partial enlarged mode Adjust the brightness of the image Zoom in out images Rotate image 0 90 180 270 Vertical flip Horizontal flip LED lamp mode toggle switch off brightness 1 brightness 2 brightness 3 Remark Brightness 3 is the brightest state F...

Page 19: ... to freeze the live image Press FREEZE to freeze the current image on the screen Press again to lift the freeze 7 3 I would like to turn on off the lamp The default state of the lamp is off press to turn it on or off There are three levels of brightness 7 4 I would like to zoom in out images Press to zoom in the image Press to zoom out the image 7 5 I would like to adjust the brightness Press to m...

Page 20: ...image The sequence of switching is 0 90 180 270 Vertical flip Horizontal flip 7 7 I would like to enlarge a part of the image 1 Press to activate the partial enlarged mode 2 Press or to move and view the partial enlarged images 3 Press to exit the partial enlarged mode ...

Page 21: ...he network list and input the password for connection default 88889999 to start the connection 8 2 Log in to the web page 8 2 1 Open the web browser and enter the default IP address 192 168 0 1 in the address bar 8 2 2 Enter the login account admin and default password 9999 and click Login 8 2 3 After the login you can do the live preview and configure the settings on the web page Caution For a fi...

Page 22: ...n Account Enter user login account default admin 2 User Password Enter user password default 9999 3 Remember user account and password Save user login account and password to the browser When you log in next time there is no need to re enter them 4 Login Log into the administrator screen on the website 1 2 3 4 ...

Page 23: ... focusing performance 3 Freeze the image Freeze the current image on the screen 4 Lamp mode toggle switch Click lamp mode toggle switch off brightness 1 brightness 2 brightness 3 5 Rotate the image Rotate the image 0 90 180 270 Flip Mirror 6 Image Mode toggle switch Select Photo Text Gray Mode 7 Logout Log out of the web page 8 Fold Expand Function Bar Click to fold expand the Function Bar on the ...

Page 24: ... 4G under Wi Fi Access Point mode 3 Device Name Device name of wireless network 4 Channel Select the channel based on different regions 5 Security Wi Fi encryption setting 6 Password Password to connect to this Wi Fi SSID Click the icon to hide display the password 7 Save Click the save your settings 8 Cancel Click to cancel the modified settings 1 2 3 4 5 6 7 8 ...

Page 25: ...evice from the list 5 Connect to Other Wi Fi Device Click to show the following window Enter the SSID and the password of the wireless device to be connected to perform the connection 6 Wi Fi Device List Display the currently found Wi Fi wireless devices 7 SSID Device name of the wireless network 8 2 4G 5G frequency band Show that the wireless network device is in the 2 4G or 5G frequency band 9 C...

Page 26: ... of the wireless network device 11 Signal Status Show the degree of the Wi Fi signal 8 3 5 System Information Network Function Descriptions Display the current network setting information of this DC W80 Click the Modify button and it will jump to the Wi Fi settings page where you can make modifications ...

Page 27: ...mation Device Function Descriptions Display current device name of this DC W80 and login settings You can modify the device name user name and password Click Save to store your change or click Cancel to cancel the modified settings ...

Page 28: ...ution and fps 2 Bitrate kbps Show or set the RTSP Bit rate 0 20000 3 Port Number Set the RTSP port 100 10000 4 Audio Setting Turn on off RTSP audio Check to turn on off RSTP audio 5 RTSP URL Show current RTSP URL connection 6 Save Click to save settings 7 Cancel Click to cancel the modified settings 1 2 3 4 5 6 7 ...

Page 29: ...resume the factory default setting as the web page setting 2 Reboot Click the reboot button and reboot the device 3 Error Code In the event of an error an error code log will be established 4 Clean If an error code appears the user may try to click the Clean button to confirm if the error will repeat itself 2 3 1 4 ...

Page 30: ... path Click Choose File to select the software file to be updated and the selected file name will be displayed after selection 3 Start Update Click to start upgrade the software 8 3 10 About Function Descriptions Display the related manufacturing information of this device including device name firmware version MAC address serial number and others 1 1 2 3 ...

Page 31: ...am 9 2 Device Requirements More than two DC W80s One computer One router depends on the network environment 9 3 Setting DC W80 9 3 1 Setting the Host DC W80 a Turn on the host DC W80 b Open the wireless network list and connect to DC W80_5G_XXXXXX XXXXXX last six digits of the MAC address Enter the password Computer DC W80 Host DC W80 Client DC W80 Client ...

Page 32: ...lick Save to apply the changes 9 3 2 Setting Client DC W80s a Turn on client DC W80s Note For initial setting please turn on only one client DC W80 at a time b Open the wireless network list and connect to DC W80_5G_XXXXXX XXXXXX last six digits of the MAC address Enter the password default 88889999 to enable the connection c Open the web browser and enter the default IP address 192 168 0 1 d Ente...

Page 33: ... list and connect to DC W80_AP_XXXXXX Enter the password default 88889999 to complete the network connection with DC W80 AP b Open Ladibug c Click to open Search Window and select Wireless Document Camera d Click to search for a DC W80 that can be connected After the search is complete click on a DC W80 in the list for connection and start the operation e To switch to another DC W80 please open th...

Page 34: ...Output Resolution DIP3 OFF Normal mode 30 25 fps applicable to general scene ON High speed mode 60 50 fps applicable to support rapidly changing scene Only applicable to 1080P DIP4 OFF 60Hz ON 50Hz 10 2 Resolution Switch Resolution 60Hz 50Hz 1920 x 1080 Default Values 3840 x 2160 1280 x 720 1024 x 768 ...

Page 35: ...the document is too close Press ZOOM on the control panel Or pull the document away from the lens And then press Auto Focus button 4 When the device is turned on the LED floodlight is off The default setting of the LED floodlight is OFF please use the control panel to set the LED floodlight as ON 5 Ladibug and other applications cannot be used simultaneously Ladibug and other applications cannot b...

Page 36: ...ormation Supplier Lumens Integration Inc 4116 Clipper Court Fremont CA 94538 United States e mail support mylumens com FCC Compliance Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired...