background image

 

CELESTA Light Engine

®

 

Instruction Manual 

Lumencor, Inc. 

                                   

Document Number 57-10015                                                 

www.lumencor.com

Summary of Contents for CELESTA Light Engine

Page 1: ...CELESTA Light Engine Instruction Manual Lumencor Inc Document Number 57 10015 www lumencor com ...

Page 2: ...rgy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Safety Certifications TUV SUD America CB Certification IEC 61010 1 2010 TUV SUD America NRTLus Certification UL 61010 1 2012 05 TUV SUD America cNRTL Certification CAN CSA C22 2 No 61010 1 2012 TUV SUD America EN Certification EN 61010 1 2010 Underwriters Laboratories ...

Page 3: ...ecautions and Warnings 3 Installation and Operating Instructions 4 Light Output Characteristics 5 Operational Specifications 6 Routine Maintenance and Troubleshooting 7 Customer Support 8 Warranty CELESTA Light Engine Instruction Manual 3 ...

Page 4: ... The light sources within the CELESTA light engine are controlled by software via one of two serial interfaces USB RS 232 or TCP to an onboard microprocessor operating Lumencor firmware The user can enable or disable each source independently by serial commands as well as change the intensity of each source independently The CELESTA light engine can be controlled by third party microscopy data acq...

Page 5: ...nt des situations ou des pratiques susceptibles d entraîner des blessures corporelles Caution Statements identify conditions or practices that could result in damage to your equipment Attention déclarations qui identifient des situations ou des pratiques susceptibles d endommager le matériel Safety Items Mesures de sécurité Warning ONLY use the power supply provided by Lumencor The Lumencor suppli...

Page 6: ...urité dans un chemin optique fermé NE PAS pointer la sortie de lumière directement sur un matériau susceptible d être inflammable ou susceptible de brûler Cela comprend tous les tissus les plastiques les tissus le papier et les liquides animaux ou végétaux Caution Use of controls or adjustments or performance of procedures other than this specified herein may result in hazardous radiation exposure...

Page 7: ...e parts inside and opening the light engine enclosure will void the manufacturer s warranty Avertissement NE PAS ouvrir l appareil Il ne contient aucune pièce réparable et l ouverture de son boîtier a pour effet d annuler la garantie Caution DO NOT set liquids on the light engine Spilled liquids may damage your light engine Attention NE PAS placer de liquide sur la source lumineuse Les liquides re...

Page 8: ... OR the fan rotor is stopped all light output channels CELESTA Light Engine Instruction Manual 8 AC Power Cords Region Part Number North America 29 10002 Europe 29 10005 United Kingdom 29 10004 Israel 29 10008 Australia New Zealand 29 10024 Figure 1 Specimen certificate of conformance C of C for CELESTA light engine The C of C identifies the color channels installed in the light engine and the ban...

Page 9: ...atus indicator display Figure 3 provides a warning indication that one or more laser sources are active and emitting invisible and or visible radiation The Remote Interlock Connector Figure 2 is provided to allow for connection of a remote interlock When this interlock is open it will shut off laser output After the interlock has been opened the Manual Interlock Reset button will need to be pushed...

Page 10: ...If the light engine is equipped with an output adapter for an SMA terminated optical fiber connect the fiber to the output adapter using the integral threaded sleeve 2 For subsequent start ups use the master power button to start or shut down the light engine Shut down can also be accomplished using the Shut Down button in the Control GUI Figure 4 3 3 3 Ethernet Connection and Control GUI The Web ...

Page 11: ...ference Document Number 57 10018 These commands can be delivered using using Transmission Control Protocol TCP to the LAN input The IP address of the light engine required for LAN communication is shown on the front panel status display Figure 3 or can be obtained using the GET IP command addressed to the RS 232 or USB serial ports The light engine software commands can also be delivered via the U...

Page 12: ...escribed in Section 3 3 3 3 Go to the SETTINGS page in the Web GUI Make sure that the USB port configuration is set to LEGACY mode and USB 5V is set to ENABLED 4 The pod must be set in CELESTA control mode The light engine control mode setting is shown in green letters at the bottom of the pod display screen If the pod is not in CELESTA control mode change the setting by holding down the MODE butt...

Page 13: ... consumption is tracked by the onboard computer If a set limit see Governor Figure 5 is exceeded either by increasing intensity settings for sources that are already on or by turning on additional sources commands will be rejected To clear the error condition reduce intensities of sources that are on or turn off additional sources Light source outputs are refined by bandpass filters The specificat...

Page 14: ... Temperature Operating 32 to 86 F 0 to 30 C Non operating 4 to 158 F 20 to 70 C Humidity Operating and non operating 0 to 80 relative humidity non condensing Altitude Operating 0 to 10 000 feet 3 048 meters Non operating 0 to 45 000 feet 13 176 meters Dimensions Size W x L x H 145 mm x 340 mm x 203 mm 5 7 in x 13 4 in x 8 0 in Weight 8 7 kg 19 1 lbs Lifetime Time for light engine output to decreas...

Page 15: ... all serial ON OFF controls are in the OFF state No light output in response to source ON command serial or TTL There are 4 interlocks that need to be closed check all of these 1 Control key must be inserted in front panel and turned to on position 2 Liquid light guide must be inserted in light output receptacle 3 Remote interlock jumper must be inserted in rear panel 4 External gate jumper must b...

Page 16: ...mance The light engine must also have been used and maintained under operating conditions consistent with the specifications given in Section 5 and observing all the Precautions and Warnings notified in Section 2 This warranty does not extend to light engines that have been subject to misuse accident tampering or improper installation Accessories including but not limited to optical fibers collima...

Reviews: