background image

Full product range & more information: 

www.lumenalights.com

 

WIRING / CONNECTION:

  

 

IMPORTANT:  

 

If Cable is buried or laid on muddy surface, it should be laid inside conduit or piping to protect from water-
logging and chemicals found in soil. If this method is not used, cable warranty will be void. 

 

It is recommended that the number of fittings on each circuit are kept to a minimum, fittings are positioned 

as evenly as possible around a circuit and each run kept as short as possible to prevent voltage drop. For 
longer cable runs, thicker cable (1.25mm or 2.5mm) may be required.  

 

Ensure the transformer has plenty of air circulation to avoid 
overheating. 

 
 

1.

 

Decide on the safe positioning of the spike light & transformer (multiple 

fittings can be powered by one transformer with correct wattage (no. 
bulbs x bulbs W = transformer wattage required).

 

2.

 

Connect the fitting to the transformer / extension cable via a waterproof 
Junction Box or Tubecon Connector (see diagram for wiring information) 

3.

 

Ensure all terminals on the connector block are secure with no stray 

wires and that the connection is watertight. 

4.

 

Connect the transformer to the mains supply (plug in or hard wire 
options) 

 240v input cable must be located inside armoured conduit.  

5.

 

Once fully installed, turn on the mains power.  
 

MOUNTING SPIKE LIGHTS:

  

 

1.

 

Connect the spike to the collar / serrated clamp joint by screwing together clockwise and securing tightly. 

2.

 

If an extension rod is used, this should be connected between the Clamp Joint / Collar and original Spike. Alternatively, 
a full extension rod complete with spike may be supplied. 

3.

 

Loosen the collar hand wheel to allow the head to point downwards to ensure the spike can be pushed from the top. 

4.

 

Dampen the ground in the area where the fitting is to be installed. 

5.

 

Carefully, push the spike into the ground to the desired depth. DO NOT PUT PRESSURE ON THE SPOTLIGHT 
HEAD.

 

 

6.

 

Gently compact the earth around the spike to ensure the spike is mounted firmly in the ground and does not move 
from side to side. 

 
ADJUSTING THE SPOTLIGHT HEAD:

  

 

The head can be adjusted and set at various angles via the serrated clamp joint - Collar. 
 

1.

 

Support the head and loosen the hand wheel located on the side of the collar by turning anti-clockwise. Turn the hand 
wheel enough to allow the head to move up and down 

(do not fully remove). 

A black rubber o-ring should be 

present. 

2.

 

Angle the head in the desired position and tighten the hand wheel. 

3.

 

To ensure a tight grip, use a pair of flat nose pliers to grip the hand wheel and tighten securely 

 a small piece of cloth 

will avoid scratching. 

 

LAMP INSTALLATION / REPLACEMENT:

  

 

1.

 

Unscrew the Cap (top section) of the Spotlight Head 

2.

 

Insert the MR16 into the bulb holder with a pushing action using the clamps as guides 

 ensure the bulb is fully inserted 

and secure. 

3.

 

Ensure the silica gel pouch is still located inside the Head to prevent condensation build up 

 replace if required. 

4.

 

Ensure the white rubber o-ring is in place between the Head Cap and Base and not twisted for a watertight seal. If for 
any reason this is missing or damaged this must be replaced (a spare is usually supplied) or contact us for replacement. 

5.

 

Replace the cap and tighten securely. 

 

IMPORTANT:

 Condensation is likely to occur due to the warmth inside the fitting produced by the lamp and the cold air 

outside. If this is noticed, on a dry day, turn off the power supply, safely remove the cap, tip out any excess water and wipe dry 

with a soft cloth. Replace the silica pouch as and when required and check the o-ring for damage.  

12v Transformer 

Output 

Reviews: