Take the round 18/2 gauge cable end and feed first through conduit

from the transformer end. DO NOT feed from Niche end because the
factory cable join of the figure eight low voltage cable and the 18/2
cable will not go through the gland in the bottom of the Niche.

Feed cable into niche, allowing sufficient free cable in niche to allow
the fitting to be placed on the poolside for re-lamping. Figure 1

NB: A maximum of 1.3m of cable can be coiled
inside the niche.

Firmly tighten cable gland on the inside of niche to seal cable
entry. Figure 2

1

FEED CABLE THROUGH

CONDUIT INTO NICHE

2

Connect cable to fixture

1. Take the round 18/2 guage cable end and trim insulation back

according to Figure 3.

100mm

8mm

FIGURE 3

Strip cable as specified above before connecting to fixture.

FIGURE 4

Feed stripped cable
end through gland
and into fixture

2. Feed stripped end of cable through fixture cable gland.

3. Terminate stripped wires into terminal block as shown in Figure 5.

Ensure Thermal Cutout remains in correct position.

Figure 5

Tighten external cable gland nuts so that they are firmly touching.

As an extra precautionary measure to ensure no moisture
comes up through the cable into the fixture, please place a
suitable neutral cure silicone around the top of the gland totally
covering the end of the cable.

FIGURE 1

ROUND CABLE END

NICHE

CONDUIT

ANTI-LEACH
CONNECTION

FIGURE EIGHT
LOW VOLTAGE
CABLE

FIGURE 2

Gland

Tighten cable gland firmly
to ensure good seal on cable.

A

START

HERE

IMPORTANT INSTRUCTIONS

MODELS

LS682-0310, LS682-0620,
LS682-0625, LS682-1030
12V 75watt max.
lamp IP68 rated

A.C.N. 010 572 773

Lumascape Lighting Industries

2006

©

LUMASCAPE

HEAD OFFICE

T 07 3286 2299 F 07 3286 6599

LUMASCAPE

SYDNEY - NSW

T 02 9519 6860 F 02 9519 8834

LUMASCAPE

MELBOURNE - VIC

T 03 9686 1900 F 03 9686 1700

ECC LIGHTING

LUMASCAPE AGENT - NZ

T 09 379 9680 F 09 308 9328

H.I. LIGHTING

LUMASCAPE AGENT - WA

T 08 9321 5422 F 08 9321 5881

NQ LIGHTING

LUMASCAPE AGENT - NTH QLD

T 07 4031 4490 F 07 4031 5933

LIGHTING PARTNERS AUSTRALIA

LUMASCAPE AGENT - SA

T 08 8232 0074 F 08 8232 0076

Lumascape Lighting Industries Pty Ltd

38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
[email protected]
W www.lumascape.com.au

Warning: The Luminaire should only be used complete with its protective shield (cover)

For Installation of fitting LS682 cable extensions

C1045 - 2006_11_REV-001

TERMINAL BLOCK

THERMAL CUTOUT

TERMINAL BLOCK
MOUNTING BRACKET

TO LAMPHOLDER

FIGURE 5

Inject here with Neutral cure
silicone.

Tighten cable gland so that both
nuts are touching.

TOP VIEW

T 1-(650)-595-LUMA(5862) 1-(650)-595-5820

LUMASCAPE USA INC

Free Call 1-866-695-LUMA(5862)

www

.lumascape.com.au

Summary of Contents for LS333ANS-2COB

Page 1: ...mer Use of electronic transformer will permanently damage luminaire All connections must be kept dry failure to do so may result in product reliability issues Installation to be done by a qualified electrician 1 2 3 4 5 6 7 A 1 Luminaire Cable Connect to a suitable power supply in accordence with local wiring rules 2 Suppluy Conduit Attach to niche gland and use to run luminaire cable back to powe...

Page 2: ...pose only 3 Do not operate the luminaires with a missing or damaged parts 4 Use only genuine Lumascape parts to replace damaged or missing components 5 Refer to instructions for installation and operating requirements 6 Ensure installation complies with local regulations Voltage insulation test megger will permanently damage product and will void warranty SAVE THESE INSTRUCTIONS SAFETY INSTRUCTION...

Page 3: ...land totally covering the end of the cable FIGURE 1 ROUND CABLE END NICHE CONDUIT ANTI LEACH CONNECTION FIGURE EIGHT LOW VOLTAGE CABLE FIGURE 2 Gland Tighten cable gland firmly to ensure good seal on cable A START HERE IMPORTANT INSTRUCTIONS MODELS LS682 0310 LS682 0620 LS682 0625 LS682 1030 12V 75watt max lamp IP68 rated A C N 010 572 773 Lumascape Lighting Industries 2006 LUMASCAPE HEAD OFFICE T...

Page 4: ...l Mount fittings must be wall mounted Luminaires can become very hot Use discretion in placement Do not touch hot lens guard or enclosure CAUTION HOT SURFACE Keep away from curtains and other combustible material Turn Off Unplug and allow to cool before replacing lamp Keep lamp away from materials that may burn Never touch lamp with bare fingers Oil from skin may damage lamp Hold lamp with soft cl...

Page 5: ... are maximum and should not be exceeded TRANSFORMER 20W 20m Circuit 1 60m Circuit 2 20W 20W 20W 20W CABLE VOLTAGE DROP Excessive voltage drop causes lamps to have a low light output The following charts and illustrations apply only to Lumascape supplied cable The distance and wattage shown are maximum and should not be exceeded 6mm2 Figure 8 PVC Cable LS604 6 9 5mm 4 2mm 3 3mm2 Figure 8 PVC Cable ...

Reviews: