u
Take the round 18/2 gauge cable end and feed first through conduit
from the transformer end. DO NOT feed from Niche end because the
factory cable join of the figure eight low voltage cable and the 18/2
cable will not go through the gland in the bottom of the Niche.
Feed cable into niche, allowing sufficient free cable in niche to allow
the fitting to be placed on the poolside for re-lamping. Figure 1
NB: A maximum of 1.3m of cable can be coiled
inside the niche.
Firmly tighten cable gland on the inside of niche to seal cable
entry. Figure 2
1
FEED CABLE THROUGH
CONDUIT INTO NICHE
2
Connect cable to fixture
1. Take the round 18/2 guage cable end and trim insulation back
according to Figure 3.
100mm
8mm
FIGURE 3
Strip cable as specified above before connecting to fixture.
FIGURE 4
Feed stripped cable
end through gland
and into fixture
2. Feed stripped end of cable through fixture cable gland.
3. Terminate stripped wires into terminal block as shown in Figure 5.
Ensure Thermal Cutout remains in correct position.
Figure 5
Tighten external cable gland nuts so that they are firmly touching.
As an extra precautionary measure to ensure no moisture
comes up through the cable into the fixture, please place a
suitable neutral cure silicone around the top of the gland totally
covering the end of the cable.
FIGURE 1
ROUND CABLE END
NICHE
CONDUIT
ANTI-LEACH
CONNECTION
FIGURE EIGHT
LOW VOLTAGE
CABLE
FIGURE 2
Gland
Tighten cable gland firmly
to ensure good seal on cable.
A
START
HERE
IMPORTANT INSTRUCTIONS
MODELS
LS682-0310, LS682-0620,
LS682-0625, LS682-1030
12V 75watt max.
lamp IP68 rated
A.C.N. 010 572 773
Lumascape Lighting Industries
2006
©
LUMASCAPE
HEAD OFFICE
T 07 3286 2299 F 07 3286 6599
LUMASCAPE
SYDNEY - NSW
T 02 9519 6860 F 02 9519 8834
LUMASCAPE
MELBOURNE - VIC
T 03 9686 1900 F 03 9686 1700
ECC LIGHTING
LUMASCAPE AGENT - NZ
T 09 379 9680 F 09 308 9328
H.I. LIGHTING
LUMASCAPE AGENT - WA
T 08 9321 5422 F 08 9321 5881
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
T 07 4031 4490 F 07 4031 5933
LIGHTING PARTNERS AUSTRALIA
LUMASCAPE AGENT - SA
T 08 8232 0074 F 08 8232 0076
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
E [email protected]
W www.lumascape.com.au
Warning: The Luminaire should only be used complete with its protective shield (cover)
For Installation of fitting LS682 cable extensions
C1045 - 2006_11_REV-001
TERMINAL BLOCK
THERMAL CUTOUT
TERMINAL BLOCK
MOUNTING BRACKET
TO LAMPHOLDER
FIGURE 5
Inject here with Neutral cure
silicone.
Tighten cable gland so that both
nuts are touching.
TOP VIEW
T 1-(650)-595-LUMA(5862) 1-(650)-595-5820
LUMASCAPE USA INC
Free Call 1-866-695-LUMA(5862)
www
.lumascape.com.au