Lumascape LS333ANS-2COB Installation Instructions Download Page 1

Warranty void if not installed as per installation instructions

INSTALLATION INSTRUCTIONS

Lumascape Lighting Industries Pty Ltd

38-44 Enterprise Street, Cleveland, QLD 4163, Australia

PO Box 1875, Cleveland D.C., QLD 4163, Australia

T

   07 3286 2299

F

   07 3286 6599

E

   [email protected]

W

 www.lumascape.com.au 

IN0157 - 18 March 2016

Copyright ©2016 Lumascape Lighting Industries Pty. Ltd.   ABN 21 010 572 773

www.lumascape.com.au

LS333ANS-2COB 

&

 LS333AS-2COB

  

IP68

A.C.N. 0105 72 773

MODEL:

 LS333ANS-2COB & LS333AS-2COB

INSTRUCTIONS COVER: 

30 V DC Ripple Free Power Supply

UNDERWATER

NOTE:

 These installation instructions are accepted in most areas. Some supply authorities may require alternative installation methods.

Should you experience any difficulty, please contact Lumascape directly: phone 07 3286 2299 or email [email protected]

IF IN DOUBT, PLEASE CALL

DANGER

ISOLATE LUMINAIRE FROM POWER

Failure to isolate power 

supply before installation or 

maintenance may result in 

fire, serious injury, electric 

shock, death and may 

damage the luminaire.

WARNING

FINISHED

APPEARENCE

It is strongly recommended to use 

Lumascape power supply or transformer

Use of electronic transformer will 

permanently damage luminaire

All connections must be kept dry; failure to 

do so may result in product reliability issues

Installation to be done by a qualified 

electrician

1

2

3

4

5

6

7

A

1

 

Luminaire Cable

Connect to a suitable power supply in accordence 
with local wiring rules.

2

 

Suppluy Conduit

Attach to niche gland and use to run luminaire 
cable back to power supply. 

3

 

Niche

Install at the time of construction. Use temporary 
fibre board shield supplied to cover niche when 
concrete is sprayed. About 1.3 m of cable can be 
coiled inside the niche.

 

4

 

Mounting Lugs

Use to hold niche in place during construction.

5

 

Mounting Ring

Used slightly adjust luminaire position and rotation 
within niche.

6

 

Luminaire

If your luminaire was ordered with the factory 
pre-set tilted optical system make sure to install it 
in the correct orientation.

7

 

Cover Plate

Place in front of luminaire before using screws to 
mount luminaire and cover plate to mounting ring.

A

 

Diffuser Installation

Open luminaire and insert diffuser between 
reflector and accessory holder. Re-seal 
luminaire. 

Single Colour Dim

Wire Colour Designation

Black

30 V DC -

Red

30 V DC +

Grey 

(1)

PWM

(1)

 

Do not connect if dimming 

   is not required

NOTE: Make sure to  pull luminaire cable 
through mounting ring before feeding 
through conduit and terminating

Summary of Contents for LS333ANS-2COB

Page 1: ...mer Use of electronic transformer will permanently damage luminaire All connections must be kept dry failure to do so may result in product reliability issues Installation to be done by a qualified electrician 1 2 3 4 5 6 7 A 1 Luminaire Cable Connect to a suitable power supply in accordence with local wiring rules 2 Suppluy Conduit Attach to niche gland and use to run luminaire cable back to powe...

Page 2: ...pose only 3 Do not operate the luminaires with a missing or damaged parts 4 Use only genuine Lumascape parts to replace damaged or missing components 5 Refer to instructions for installation and operating requirements 6 Ensure installation complies with local regulations Voltage insulation test megger will permanently damage product and will void warranty SAVE THESE INSTRUCTIONS SAFETY INSTRUCTION...

Page 3: ...land totally covering the end of the cable FIGURE 1 ROUND CABLE END NICHE CONDUIT ANTI LEACH CONNECTION FIGURE EIGHT LOW VOLTAGE CABLE FIGURE 2 Gland Tighten cable gland firmly to ensure good seal on cable A START HERE IMPORTANT INSTRUCTIONS MODELS LS682 0310 LS682 0620 LS682 0625 LS682 1030 12V 75watt max lamp IP68 rated A C N 010 572 773 Lumascape Lighting Industries 2006 LUMASCAPE HEAD OFFICE T...

Page 4: ...l Mount fittings must be wall mounted Luminaires can become very hot Use discretion in placement Do not touch hot lens guard or enclosure CAUTION HOT SURFACE Keep away from curtains and other combustible material Turn Off Unplug and allow to cool before replacing lamp Keep lamp away from materials that may burn Never touch lamp with bare fingers Oil from skin may damage lamp Hold lamp with soft cl...

Page 5: ... are maximum and should not be exceeded TRANSFORMER 20W 20m Circuit 1 60m Circuit 2 20W 20W 20W 20W CABLE VOLTAGE DROP Excessive voltage drop causes lamps to have a low light output The following charts and illustrations apply only to Lumascape supplied cable The distance and wattage shown are maximum and should not be exceeded 6mm2 Figure 8 PVC Cable LS604 6 9 5mm 4 2mm 3 3mm2 Figure 8 PVC Cable ...

Reviews: