40
FAULT CLEARANCE
Before carrying out any repair work on the machine:
- Switch off the machine.
- Disconnect the AC power supply.
Motor does not start:
AC supply is interrupted.
Reconnect the AC supply.
Switch or connector is defective. Schalter bzw. Stecker ersetzen.
Motor switches off
during the work.
Motor has shut down because it
is overloaded.
Causes:
The AC supply connection is too
long or has an insufficient cross-
section (<2.5 mm²).
Wait 5 to 10 minutes until the
motor has cooled down and then
start the machine again.
Replace the AC supply connec-
tion with a cable having a cross-
section ≥ 2,5 mm
2
.
Motor is turning in the
wrong direction
Incorrect phase rotation.
Change the position of the pha-
se rotation selector.
Splitter does not
function although
motor is turning.
Hydraulic valve has not opened
because of a loose connection.
Tighten the loose connection.
The hydraulic oil level is too low. Top up the hydraulic oil.
The firewood splitter is
working but is making
unusual noises or is
vibrating excessively.
The hydraulic oil level is too low. Top up the hydraulic oil.
Have your firewood splitter checked by a qualified specialist if the problem is not
corrected by these measures or if the problem is not covered in the table..
INSTRUCTIONS FOR PROTECTION OF THE ENVIRONMENT
Old electrical devices are work material; hence, they do not belong
in the domestic garbage! We, therefore, request you to support us
with your active contribution towards conservation of resources and
environmental protection and to dispense of this device at the arranged
places for return – if existent.
FAULT CLEARANCE
ENVIRONMENT PROTECTION
Summary of Contents for HOS8-230
Page 2: ......
Page 4: ...FR IT DE GB 3 A B B 5 6 7 8 9 10 A A 11 A C B...
Page 5: ...1 5 6 9 10 11 15 13 17 20 12 4 19 18 14 4 3 2 21 16 7 8 12 13...
Page 25: ...24...