background image

Power supply

Stereo inputs/outputs

9VDC center negative
Protected against wrong polarity
Current consumption: 250mA

Input impedance: 470 kOhm
Output impedance: 470 Ohm
Maximum input/output levels: +7dBu

Save preset

Once the effect is set as desired, press and hold both BYPASS and TEMPO switches simultaneously for 1 second.
The fast blinking of the BYPASS led indicates the “Save preset” mode.
Then, turn the RHYTHM knob to the desired preset number position. Finally, press and hold BYPASS and TEMPO
switches simultaneously

for 1 second. Now, the preset has been saved.

again

1sec

“Save preset” mode can be cancelled, without the saving action. To do this, follow instructions as in “Exit
preset”.

To load a preset, press and hold the BYPASS switch. The fast blinking of the white BYPASS led indicates the
“Load preset” mode.
Without releasing the switch, turn the RHYTHM knob to the desired preset number position, and then release the
BYPASS switch. Now, the preset is loaded and running.

Load preset

hold

release

Audio quality

Other

Frequency response: 20Hz to 20kHz
A/D & D/A: 24 bit, 48kHz
Ultra-low noise analog front-end
Signal to noise ratio: 114dB

True bypass with electromechanical relays
Expression pedal resistance: 10kOhm

The BYPASS led blinks in a short-long-short-long sequence, which indicates that the device is running a preset.
While running a preset the different knobs and parameters may be changed, which doesn’t change the preset
that is saved in memory.

To stop running the preset, press both BYPASS and TEMPO switches shortly (less than 1 second).
From that time on, the device uses the parameters that are set by the knobs and controls, and stops running
the preset. The BYPASS led stops blinking with the preset sequence.

Exit preset

#1

#2

#3

#4

#5

#8

#6

#7

PRESETS

1sec

#1

#2

#3

#4

#5

#8

#6

#7

< 1sec

TECHNICAL SPECIFICATIONS

QUICK START GUIDE

tremolo / oscillator

Reviews: