EN
HOW THE COOKER
HOOD WORKS
6 - key push button panel ( fig. 12)
A: Light ON/OFF key
B: Motor ON ( I speed ) /OFF key
C: II speed key
D: III speed key
E: IV speed key
F: 10 minutes timer
The extractable unit is open manually by pushing
the glass downwards, as shown in figure 4; in the
same way, push the glass downwards to close it,
until it is completely closed .
The motor and the lights are started by the push
button panel (fig.12).
The motor and the light are automatically switched
off when the extractable unit is closed, in case they
are on.
TIMING
As a result of the new EU65 “Energy label” and
EU66 “ Ecodesign” regulations issued by the Eu-
ropean Commission, which came into force as from
January 1st, 2015 , our products have been adap-
ted to comply with these new requirements.
All of the models complying with the energy label
requirements, are equipped with new electronics
including a timer device for suction speeds control,
when the air capacity exceeds 650m³/h.
Internal motor models, with maximum air capacity
higher than 650m³/h, are equipped with a timer de-
vice that automatically switches the suction speed
from 4th to 3rd speed, after 6 minutes operation.
External motor models are equipped with remote
motors that , as for internal motor versions, include
a timer device that switches down the suction spe-
ed when it exceeds 650 m³/h. (See External Motors
Instructions).
Remote motors, whose air capacity exceeds
650m³/h at both 4th and 3rd speed , will have the
following by default timer control functions:
The suction speed is automatically switched from
4th to 2nd speed, after 6 minutes operation.
If the appliance is working at 3rd speed, it is au-
tomatically switched to 2nd speed, after 7 minutes
operation. Operation speeds can also be changed
during operation.
The energy consumption of the appliance in stand –
by mode is lower than 0.5W.
Other functions:
Automatic turn off:
After 4 hours of continuous operation from the last
setup, the appliance turns off automatically.
Grease filters saturation:
After 30 hours of operation, the speed indica tors
“D”
will all flash simultaneously, signaling the gre-
ase filters saturation. To reset this alarm, hold the
“TIMER” button down for at least 3 seconds, while
the extractable unit is open.
19
TRENTO
Summary of Contents for TRENTO
Page 2: ......
Page 6: ...DESCRIZIONE DELL APPARECCHIO IT 6 TRENTO...
Page 15: ...DESCRIPTION OF THE APPLIANCE EN 15 TRENTO...
Page 24: ...VUE DIMENSIONNELLE DE VOTRE APPAREIL FR 24 TRENTO...
Page 33: ...DESCRIPCI N DEL APARATO ES 33 TRENTO...
Page 42: ...GER TEBESCHREIBUNG DE 42 TRENTO...
Page 51: ...BESCHRIJVING VAN HET APPARAAT NL 51 TRENTO...
Page 58: ...IMMAGINI IMAGES IMAGES AFBEELDINGEN IM GENES BILDER 58 TRENTO...
Page 59: ...Fig 4 Fig 1 Fig 5 Fig 6 59 TRENTO Fig 2 Fig 3...
Page 60: ...60 TRENTO Fig 9 Fig 10 Fig 11 Fig 12 Fig 7 Fig 8...
Page 61: ...Fig 14 61 TRENTO Fig 13...
Page 62: ...62 TRENTO...
Page 63: ...63 TRENTO...
Page 64: ...90007571100 04 18...