luft XC250 Manual Download Page 5

4

Manual XC250

EN

Carefully read the operating manual before using the device
and keep it within reach!

• Do not use the device in atmospheres containing oil, sulphur,

chlorine or salt.

• Never use the device for measurements at live parts.

• Protect the infrared sensor from dirt.

• Ensure that all connection cables are protected from

damages (e.g. from kinks or crushing).

• Protect the device from permanent direct sunlight.

• Observe the storage and operating conditions (see chapter

Technical data).

Intended use

Only use the infrared thermohygrometer XC250 for indoor
measurements of temperature and humidity. Here, read and
observe the technical data.
To use the device for its intended use, only connect and use
accessories and spare parts which have been approved by
Lufft

®

.

Improper use

Do not use the device in potentially explosive atmospheres, or for
measurements in liquids. Never point the device at people or
animals. Lufft

®

 accepts no liability for damages resulting from

improper use. In such a case, entitlements to a warranty are
forfeited. Any unauthorised modifications, alterations or
structural changes to the device are forbidden. 

Personnel qualifications

People who use this device must:

• have read and understood the operating manual, especially

the Safety chapter.

For maintenance or repair work which requires the housing
to be opened, contact Lufft

®

 customer service. Devices

which have been opened unlawfully are void of any warranty
and warranty claims.

Residual risks

Risk from laser radiation!

Class 2 laser radiation. 
Lasers of class 2 only radiate in the visible range and
during continuous wave operation (lasting beam) no
more than 1 milliwatt (mW) of output will be emitted.
Looking directly into the laser beam for a longer period
of time (more than 0.25 seconds) can cause damage to
the retina.
Avoid looking directly into the laser beam. Never look
into the laser beam using optical aides. Do not
suppress the winking reflex when looking into the laser
beam unintentionally. Never point the laser beam at
people or animals.

Danger!

Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Danger!

The device is not a toy and does not belong in the hands
of children.

Danger!

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way.
Observe the personnel qualifications.

Caution!

To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.

Safety

Summary of Contents for XC250

Page 1: ...p p p p p pou ou ou ou ou ou ou u ou ou ou ur r r r r r r r r r la la la la la la la la la la p p p p p p p p p p pr r r r r r r r r r ci ci ci ci ci ci ci ci ci cisi si si si si si si si si ion on on...

Page 2: ...results Lufft Warranty The warranty is for 12 months Damages caused by incorrect use by untrained people or startup by unauthorised people are excluded from the warranty The device complies with the...

Page 3: ...urface temperature of the measuring object and the dew point temperature within the measurement environment A minimum maximum and average function is available for the direct analysis of the measured...

Page 4: ...Technical data Parameter Value Air temperature NTC Measuring range 20 to 50 C Tolerance 0 2 C 0 to 40 C otherwise 0 4 C Resolution 0 1 C Object temperature Pyrosensor Measuring range 70 to 380 C Toler...

Page 5: ...Personnel qualifications People who use this device must have read and understood the operating manual especially the Safety chapter For maintenance or repair work which requires the housing to be ope...

Page 6: ...bag to transport the device safely Storage When the device is not being used observe the following storage conditions dry protected from dust and direct sunlight with a plastic cover to protect it fr...

Page 7: ...device is ready for operation The displayed units are based on the settings of the last utilization 4 Select the desired measuring mode 5 Point the device at the area to be measured The measured value...

Page 8: ...measured value display 18 indicates either the humidity or the dew point To set the unit see Humidity display configuration on page 10 IR DP mode Risk from laser radiation Class 2 laser radiation Las...

Page 9: ...l 2 2 Confirm with the OK button 12 CAL1 IR mode Specifying the temperature offset value range 10 to 10 C or 18 to 18 F Set the degree of emission value range 0 1 to 1 0 1 Enter the temperature offset...

Page 10: ...e more the surface temperature drops the faster increases the repetition frequency of the acoustic and visual signals Maximum repetition frequency is triggered when reaching the lower alarm limit TdP...

Page 11: ...values cannot be saved on the device itself In order to save measured values the device has to be connected to a PC via a USB cable using the SmartGraph software 1 Briefly press the OK button 12 The...

Page 12: ...adiate Many organic materials and surfaces have a degree of emission of approx 0 95 Metal surfaces or shiny materials have a lower degree of emission and therefore only yield inaccurate measured value...

Page 13: ...isit the website www smartgraph3 de download 2 Double click the downloaded file 3 Follow the instructions of the installation wizard Starting the PC software 1 Start the SmartGraph3 software 2 Switch...

Page 14: ...il of 27th January 2003 concerning old electrical and electronic equipment After the end of its use please dispose of this device in a manner appropriate to the relevant legal requirements In the Euro...

Page 15: ...820 E Mason St A Santa Barbara CA 93103 Tel 01 919 556 0818 Fax 01 805 845 4275 E Mail sales lufftusainc com www lufft com Lufft China Shanghai Of ce Lufft Shanghai Measurement Control Technology Co...

Reviews: