Figure 11: Pressure
Settings
Figure 12: Wind
Settings
10.2.5 Pressure,
Offset:
Absolute offset on the measurement in the unit of the accompanying
channel.
Interval:
Time in minutes for the minimum, maximum and average value
calculation interval.
Altitude:
Enter the local altitude in meters here for the correct calculation of
relative air pressure (referenced to sea level).
10.2.6 Wind and Compass Settings
Offset:
Absolute offset on the measurement in the unit of the accompanying
channel.
Interval:
Time in minutes for the minimum, maximum and average value
calculation interval.
Windspeed min:
Approach velocity onto the wind meter with effect from which a
measurement is transmitted, in the unit of the accompanying channel.
Heater mode:
The device can be configured for heating in different operating modes.
Configure as ‘automatic’ in normal operating mode. You can find a
precise description of the operating modes on page 39.
Local declination: Dependent on the location of the installation; the local declination of the
earth magnetic field has to be considered.
Enable Compass for wind-direction correction:
With activated compass correction all wind direction values will be
corrected according to the alignment of the sensor, as evaluated by the
compass.
Note:
The offset is not used for the wind meter at present because on-site calibration is not
possible in this case.