Operating Instructions
Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
137
19.8.7 Configuration Commands
Command Examples are shown for unit ID 01
19.8.7.1 Transmission Interval for Continuous Measurement
Command identifier:
MI
Parameter:
interval in seconds (min. 10, max. 43200, default 60)
Request command example:
Command: *0100MI<CR><LF>
Response: *0001MI=60<CR><LF>
The command requests the current setting of the result transmission interval
Setting command example (to be preceded by the write enable command)
Command: *0100MI=60<CR><LF>
Response: *0001MI=60<CR><LF>
The command sets the interval for automatic measurement result transmission (19.8.6.2) in
seconds.
19.8.7.2 Option Append Wind Data (MWD) to XDR Sentence
Command identifier:
GW
Parameter:
0 = wind data off, 1 = wind data on
Request command example:
Command: *0100GW<CR><LF>
Response: *0001GW=0<CR><LF>
The command requests the current setting of the wind data option.
Setting command example (to be preceded by the write enable command)
Command: *0100GW=1<CR><LF>
Response: *0001GW=1<CR><LF>
The command sets the wind data option.
19.8.7.3 Select Spot Values or Average Values of Wind Data
Command identifier:
JW
Parameter:
0 = wind data spot values, 1 = wind data average values
Request command example:
Command: *0100JW<CR><LF>
Response: *0001JW=1<CR><LF>
The command requests the current setting of the wind data average setting.
Setting command example (to be preceded by the write enable command)
Command: *0100JW=0<CR><LF>
Response: *0001JW=0<CR><LF>
The command sets the wind data average or spot transmission.