Lucoro Broadcast TX-FMBR1 Technical Manual
Page 18
Read TX Frequency:
Command Type: Request
Identifier: 101
0x65
Command Description: This command is used to get the current TX Frequency
setting
Byte 1 to 2:
Value of the centre Frequency expressed in NNNN x100kHz
875 to 1080. Default = 98.0
Byte 1 is the MSB and Byte 2 is the LSB
For example, 98.0 should be coded as 0x03, 0xD4
Notes:
Read RX Frequency:
Command Type: Request
Identifier: 102
0x66
Command Description: This command is used to get the current Receive Frequency
setting
Byte 1 to 2:
Value of the Frequency expressed in NNNN x100kHz
875 to 1080. Default = 980
Byte 1 is the MSB and Byte 2 is the LSB
For example, 98.0 should be coded as 0x03, 0xD4
Notes:
Read RF Output Power:
Command Type: Request
Identifier: 103
0x67
Command Description: This command is used to get the current Transmission RF
Output Power setting
Byte 1 to 2:
RF Output Power level expressed in NNNN mW
100 to 1100mW
Byte 1 is the MSB and Byte 2 is the LSB
Notes: