3. CONFIGURATION
In addition, you can continue with this configuration:
•
Activating the
Enable I/O extension
function allows you monitor the binary I/O inputs on
the router.
•
Selecting the
Enable XC-CNT extension
lets you monitor the expansion port CNT inputs
and outputs status.
•
Selecting
Enable M-BUS extension
and entering the
Baudrate
,
Parity
and
Stop Bits
lets
you monitor the meter status connected to the expansion port MBUS status.
Item
Description
Baudrate
Communication speed
Parity
Control parity bit:
•
none
– Data will be sent without parity.
•
even
– Data will be sent with even parity.
•
odd
– Data will be sent with odd parity.
Stop Bits
Number of stop bits.
Table 53: SNMP configuration – MBUS extension
Parameters
Enable XC-CNT extension
and
Enable M-BUS extension
cannot be checked
at the same time.
Selecting
Enable reporting to supervisory system
and entering the
IP Address
and
Period
lets you send statistical information to the monitoring system, R-SeeNet.
Item
Description
IP Address
IP address
Period
Period of sending statistical information (in minutes).
Table 54: SNMP Configuration – R-SeeNet