Understanding Syslog messages
Disconnect codes and their meanings
MAX Administration Guide
A-9
103
MAX disconnected call because of a validation failure on outgoing call-
back call.
105
Session timeout on the basis of encapsulation negotiations.
106
MP session timeout.
115
Instigating call no longer active.
120
Requested protocol is disabled or unsupported.
150
Disconnect requested by RADIUS server.
151
Call disconnected by local administrator.
152
Call disconnected via SNMP.
160
MAX disconnected V110 call because of it a timeout condition was trig-
gered.
170
Timeout waiting to authenticate far end.
180
User disconnected by executing Do Hangup from VT100 interface.
171
MAX unit disconnected call when the PPP interface was released.
180
MAX unit disconnected call when user invoked the MAX unit DO
Hangup command.
181
Call cleared by MAX.
185
Signal lost from far end, typically because the far end modem was turned
off.
190
Resource has been quiesced.
195
Maximum duration time reached for call.
201
MAX has low memory.
210
MAX modem card stops working while it has calls outstanding.
220
MAX requires CBCP, but client does not support it.
230
MAX deleted Vrouter.
240
MAX disconnected call on the basis of LQM measurements.
241
MAX cleared backup call.
250
IP FAX call cleared normally.
251
IP FAX call cleared because of low available memory.
252
MAX detected an error for an incoming IP FAX call.
253
MAX detected an error for an outgoing IP FAX call.
254
MAX detected no available modem to support an IP FAX call.
255
MAX detected problem opening IP FAX session.
256
MAX detected a problem when performing a TCP function during an IP
FAX call.
257
IP FAX session cleared abnormally.
258
MAX detected problem when parsing telephone number for IP FAX call.
260
MAX detected problem when decoding IP FAX variables.
Disconnect