12-14
Stinger®
Administration Guide
Diagnostic Testing
OAM testing
Entry=478ea0, Linear Port=28 vpi=0, vci=3 state=Up loopTx=0 loopRx=0
Segment Continuity=READY End2End Continuity=READY isVpc=No
Entry=478fe0, Linear Port=28 vpi=0, vci=4 state=Up loopTx=0 loopRx=0
Segment Continuity=READY End2End Continuity=READY isVpc=No
Entry=478d60, Linear Port=28 vpi=0, vci=35 state=Up loopTx=0 loopRx=0
Segment Continuity=READY End2End Continuity=READY isVpc=No
hdsl2-1/4>
oam -l 25 0 35 s 1
hdsl2-1/4> Sending F5 OAM segment loopback cell, Id=0
Received our F5 OAM segment loopback cell, Id=0
OAM: received our F5 OAM segment loopback #0
Running F4 and F5 loopback tests using the
atm-oam
profile
To run an F4 or F5 loopback test, you set the parameters in the
loopback-config
subprofile. You can test multiple ATM circuits using a single
atm-oam
profile.
Sample F4 OAM loopback test
The following sample commands configure four end-to-end, F4 loopback tests on
slot 10, port 1, VPI 2, with a time interval of 30 minutes between each test and two
cells per test:
admin>
new atm-oam {{ 1 10 1} 2 32769}
ATM-OAM/{{ 1 10 1} 2 32769} read
admin>
set loopback-config enabled = yes
admin>
set loopback-config loopback-level = end-to-end
admin>
set loopback-config loopback-cells-per-test = 2
admin>
set loopback-config total-loopback-tests = 4
admin>
write
ATM-OAM/{{ 1 10 1} 2 32769} written
Sample F5 OAM loopback test
The following sample commands configure four end-to-end, F5 loopback tests on
slot 10, port 1, VPI 2, and VCI 35 with a time interval of 30 minutes between each
test and two cells per test:
admin>
new atm-oam {{ 1 10 1} 2 35}
ATM-OAM/{{ 1 10 1} 2 35} read
admin>
set loopback-config enabled = yes
admin>
set loopback-config loopback-level = end-to-end
admin>
set loopback-config loopback-cells-per-test = 2
admin>
set loopback-config total-loopback-tests = 4
admin>
set loopback-config test-iteration-interval = 30
admin>
write
ATM-OAM/{{ 1 10 1} 2 35} written
Testing multiple ATM circuits
The following examples illustrate how multiple ATM circuits can be tested by means
of a single profile. Assume that the shelf value is 1 and the slot value is 15.
Summary of Contents for Stinger
Page 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Page 4: ......
Page 16: ......
Page 18: ......
Page 62: ......
Page 82: ......
Page 96: ......
Page 182: ......
Page 218: ......
Page 236: ......
Page 252: ......
Page 288: ......
Page 350: ......
Page 362: ......
Page 374: ......