physical-address* = { any-shelf any-slot 0 }
enabled = no
sparing-mode = inactive
ignore-lineup = system-defined
line-config = { 0 1 15 static { any-shelf any-slot 0 } coe no not-eligible
midd+
The default
line-config
subprofile is listed below with its defaults:
[in SHDSL/{ any-shelf any-slot 0 }:line-config]
trunk-group = 0
nailed-group = 1
vp-switching-vpi = 15
activation = static
call-route-info = { any-shelf any-slot 0 }
unit-type = coe
ntr-enabled = no
clock-source = not-eligible
clock-priority = middle-priority
loop-back = none
margin = 2db
snext-margin = disable
rate-mode = auto
min-rate = 72000
max-rate = 2312000
gshdsl-standard-network-type = north-american-annex-a
annexb-anfp-enabled = no
gshdsl-psd-type = symmetric
master-binding-port = no
Parameter
Setting
name
Name of the interface. The default value is the interface
address in
shelf:slot:item
format (for example,
1:2:1
),
but you can assign a text string of up to 16 characters.
physical-address
Physical address of the interface in the Stinger unit.
enabled
Enable or disable the interface. Specify one of the following
values:
■
no
(the default)—Line is disabled until you activate it in
the
shdsl
profile.
■
yes
—Line is enabled.
ignore-lineup
Value of the
ignore-lineup
parameter. Possible values are:
■
system-defined
—Ignore line up value is picked from
system profile.
■
no
—Do not ignore line up.
■
yes