Enclosure and Component Installation
Mounting the enclosure on a pole
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
3
-9
2
Position the mounting hardware against the pole so that the center mounting
bolt hole of the top pole mounting bracket is centered on the pole at least 67
inches (1.7 meters) above the ground (see Figure 3-7). Mark the location for the
top mounting bolt hole on the pole and use an 11/16in. drill bit, or a drill bit that
is 0.625in. to 0.7in. (15.875mm to 17.78mm) in diameter, to drill the hole for the
top mounting bolt through the center of the pole.
Figure 3-7. Top and bottom pole mounting bolts
3
Use the top mounting bolt to temporarily install the mounting hardware on the
pole. Allow the hardware to hang vertically and mark the location for the lower
mounting bolt on the pole.
4
Remove the mounting hardware from the pole and drill the hole for the lower
mounting bolt. Then permanently mount the hardware, using the top and
bottom mounting bolts.
Note
The threaded end of the bolt should extend at least 1 inch beyond the back
of the pole.
Top mounting bolt
Washer
Bottom mounting bolt
67 in.
(Minimum)
Nut
to ground
24.0 in.
Rear mount bracket
(if available)
Lock
washer