version mismatch
....................................................................................................................................................................................................................................
version mismatch
The firmware in the indicated circuit pack does not match the active
software generic running on the NE.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Minor (MN)
AID (type)
Slot
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
NSA
Alarm Entity
Type
EQPT
Description
version mismatch
Likely Cause
A circuit pack with a newer version of firmware
was installed in a shelf and did not update
automatically.
A new circuit pack was inserted into the shelf and
the software generic in the dormant area of the
SYSCTL was corrupted or did not match the
generic running on the shelf and the firmware did
not update automatically.
Visible
indication
Lighted
MN/ABN
LED on SYSCTL faceplate and a
continuously lighted
FAULT
LED on the alarmed
circuit pack.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
3 - 9 5