Procedure 5-56: Clear
″
version mismatch
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
version mismatch
alarm indicated
by a lighted Minor (
MN/ABN
) LED on the SYSCTL faceplate, and
reported as minor in the WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Complete the following steps to clear a
version mismatch
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the version mismatch alarm in the resulting alarm list.
............................................................................................................................................................
2
Refer to the Probable Cause column in the alarm list, determine the
circuit pack affected, and note the corresponding AID.
............................................................................................................................................................
3
Un-seat and then re-seat the alarmed circuit pack.
Result:
SYSCTL reinitializes the pack and should
automatically update the firmware on the newly installed
pack.
............................................................................................................................................................
4
From the WaveStar
®
CIT System View, click the
Alarm List
button
and click
Refresh
.
............................................................................................................................................................
5
Is the
version mismatch
alarm still present?
If...
Then...
Yes
Continue with
No
Proceed to
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 6 1