VCG Failure of LCAS Protocol (Sink)
....................................................................................................................................................................................................................................
VCG Failure of LCAS
Protocol (Sink)
This alarm indicates an LCAS-enabled VCG receive protocol failure.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Minor (MN)
AID (type)
VCG
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
VCGFOPR
Effect on
Service
SA
Alarm Entity
Type
VCG
Description
VCG Failure of LCAS Protocol (Sink)
Likely Cause
A combination of link failures and provisioning
actions that interfered with each other, or a
misalignment between the source and sink end of
the Sequence Numbers and Member Status
information.
Visible
indication
Lighted
MN/ABN
LED on SYSCTL faceplate and a
continuously lighted
FAULT
LED on the alarmed
circuit pack.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 9 2
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005