Pluggable Transmission Module removed
....................................................................................................................................................................................................................................
Pluggable Transmission
Module removed
Specified pluggable transmission module was removed from the
circuit pack.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Minor (MN)
AID (type)
Socket
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
CR = SA
MN = NSA
Alarm Entity
Type
EQPT
Description
Pluggable Transmission Module removed
Likely Cause
An unprotected pluggable transmission module
carrying service was removed from the circuit
pack: CR (SA).
A protected pluggable transmission module was
removed from the circuit pack or an unprotected
pluggable transmission module NOT carrying
service was removed from the circuit pack: MN
(NSA).
Visible
indication
Lighted
CR/MJ
or
MN/ABN
LED on SYSCTL
faceplate, a continuously lighted port LED on the
socket, and a flashing
FAULT
LED on the circuit
pack.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 8 2